THOMPSON LEARNING • ELECTRICAL THEORY
Basic AC Theory for Electricians
A corrected lesson on alternating current, magnetic and electric fields, inductance, capacitance, impedance, and power.
Replacement edition • September 8, 2026 • Prepared for editorial review
Lesson contents
- Alternating current, direct current, and waveforms
- Why transmission voltage matters
- Current and magnetic fields
- Electromagnetic induction and AC generation
- Frequency, period, and wavelength
- Instantaneous, peak, RMS, and average values
- Phase, leading, and lagging
- Ohm’s law for a resistive AC circuit
- Inductance, self-induction, and coil losses
- Current growth and decay in an RL circuit
- Mutual inductance and series-connected coils
- Electric fields and capacitance
- Real capacitors: ratings, construction, and losses
- RC charging, discharging, and the time constant
- Capacitors in series and parallel
- Inductive and capacitive reactance
- Net reactance in a series circuit
- Impedance and Ohm’s law for AC
- Real, reactive, and apparent power
- Power factor and practical correction
- Complete series-RLC example
- Complete parallel-RLC example
- Resonance and the limits of the simple model
- Formula and unit reference
On a small screen, scroll a diagram or table sideways to see it at a readable size.
Before you begin
This lesson connects three ideas: a changing current produces a changing magnetic field; a changing magnetic flux can induce a voltage; and inductors and capacitors store and return energy. Those ideas explain why voltage and current do not always rise and fall together in an AC circuit.
By the end, you should be able to distinguish AC from DC, read a sine wave, convert between peak and RMS values, identify leading and lagging current, calculate reactance and impedance, and solve basic series and parallel RLC circuits. You will also distinguish real power, reactive power, and apparent power.
Conventions used throughout: Current arrows indicate conventional current, the direction positive charge would move. Electron drift in a metal is opposite that direction. Capital V and I denote RMS magnitudes unless marked otherwise; lowercase v(t) and i(t) are instantaneous values. Reactances XL and XC are positive magnitudes. Signed net series reactance is X = XL − XC.
The AC formulas below assume ideal, linear components driven by a single-frequency sine wave, except where another condition is explicitly stated. A circuit with switching electronics, magnetic saturation, harmonics, or substantial parasitic effects may require a more detailed model. Use the calculator’s full precision for intermediate steps and round the final result.
Safety boundary: These examples teach circuit analysis; they are not instructions to construct or energize the illustrated circuits. Capacitors can retain hazardous energy after disconnection, and an interrupted inductor current can produce a high voltage. Real equipment requires suitable ratings, protective devices, approved de-energization and discharge procedures, and verification before contact.
1. Alternating current, direct current, and waveforms
Electric current is the rate at which charge passes a point. One ampere is one coulomb per second. Direct current flows in one direction, although its magnitude may be steady or may vary. Alternating current reverses direction. A sine wave is the main AC waveform used in this lesson, but square and other repeating waveforms can also be alternating.
I = Δq / Δt for constant current over an interval
If 0.5 C moves in one direction in 0.5 s and another 0.5 C moves in the opposite direction in the next 0.5 s, the current has a magnitude of 1 A during each interval. The signed net charge transfer over the full second is zero. That example is a symmetrical square-wave current, not a sine wave.
A voltage waveform is a graph of voltage against time. A positive value means that the measured polarity agrees with the chosen reference; a negative value means the opposite. The same sign convention applies to current direction.
Technical background: [R1].
2. Why transmission voltage matters
A conductor with resistance converts some electrical energy into heat. Its resistive loss depends on RMS current, not on whether the system is labeled AC or DC.
Ploss = I2R
For a fixed amount of transmitted real power and a fixed power factor, raising voltage reduces current. Halving current reduces I2R loss to one-fourth when conductor resistance is unchanged.
AC had an important historical advantage because transformers could efficiently change its voltage. A conventional transformer needs changing magnetic flux and cannot continuously transform steady DC directly. Modern electronic converters can change DC voltage, and high-voltage direct-current transmission also has important applications. It is therefore inaccurate to treat all DC transmission as inherently inefficient.
An ideal transformer illustrates the relationship: voltage ratio equals turns ratio, while current ratio is the inverse. Input and output power are equal only in the ideal model; real transformers have losses.
V2 / V1 = N2 / N1 and I2 / I1 = N1 / N2
3. Current and magnetic fields
A straight current-carrying conductor
A current-carrying wire produces a magnetic field around itself. Around an ideal long, straight wire, the field forms concentric circles in planes perpendicular to the wire. A small compass aligns with the local net magnetic field; near a sufficiently strong wire field it points tangent to one of these circles.
Use the right-hand grip rule: point your right thumb in the direction of conventional current. Your curled fingers indicate the magnetic-field direction. In an end view, a dot means current toward you; a cross means current away from you.
Some older lessons use electron flow with a left-hand grip rule. That is an equivalent description only when the current arrow is reversed. Do not mix the electron-flow convention with a conventional-current diagram. A three-finger motor-force rule is a different rule and should not replace the conductor grip rule.
For a long, straight wire in a uniform surrounding medium, the field magnitude is approximately B = μI/(2πr), where r is the distance from the wire and μ is the medium’s permeability. The field is weaker farther away; it is not equal everywhere around the wire.
Adjacent conductors
Parallel wires carrying current in the same direction attract. Their field contributions oppose between the wires and reinforce outside them. Opposite-direction currents repel; their field contributions reinforce between the wires. These statements describe the magnetic force on the conductors, not a literal pushing of drawn field lines.
Coils and electromagnets
In a coil, the fields of the individual turns combine. A solenoid has a north and a south pole. Curl the fingers of your right hand with conventional current around the turns; your thumb indicates the coil’s north end. Viewed from that end, conventional current circulates counterclockwise. Reversing the current reverses the magnetic polarity.
Magnetic behavior depends on turn count, current, geometry, core material, and any air gap. A magnetic core can concentrate flux, but its response is not unlimited: saturation, temperature, and frequency affect real performance. Copper resistance, hysteresis, and eddy currents produce real power losses.
4. Electromagnetic induction and AC generation
Electromotive force, or EMF, is energy supplied per unit charge by a source; its unit is the volt. An induced EMF is associated with a change in magnetic flux linkage. Relative motion between a conductor and a magnetic field is one way to produce that change. Changing the field through a stationary coil is another, as in a transformer.
Faraday’s law for N turns linking the same flux is:
eind = −N dΦ/dt
The minus sign expresses Lenz’s law: the induced effect opposes the change in flux that produces it. It does not mean an inductor always opposes the existing current. When current is falling, the inductor tends to keep it flowing in the same direction.
A metal already contains mobile conduction electrons. Induction is not a process in which a moving magnetic field sweeps electrons out of atomic orbits. For a moving conductor, magnetic forces act on charge carriers; for a changing field, an induced electric field can drive them.
The rotating-loop model
Take a loop of area A rotating at constant angular speed ω in a uniform field B. Let θ be the angle between the field and the loop’s area-normal direction. The normal is perpendicular to the plane of the loop.
Φ = BA cos θ θ = ωt
v(t) = NBAω sin(ωt) = Vpk sin(ωt)
At 0° and 180°, the flux has an extreme value but its instantaneous rate of change is zero, so the induced voltage is zero. At 90° and 270°, the flux passes through zero and changes most rapidly, producing the positive and negative voltage peaks. One full electrical cycle contains two half-cycles, also called alternations.
A voltage can exist at an open generator terminal. Current also requires a connected conducting circuit. Mechanical energy supplied to a loaded generator provides its electrical output and losses.
5. Frequency, period, and wavelength
Frequency f is the number of cycles per second, measured in hertz (Hz). Period T is the time for one cycle. Angular frequency ω measures the same repetition rate in radians per second.
T = 1/f f = 1/T ω = 2πf
At 60 Hz, T = 1/60 s = 0.01667 s = 16.67 ms. A quarter-cycle lasts about 4.17 ms. At 2 Hz, one cycle lasts 0.5 s.
In the simple two-pole generator model, one mechanical revolution produces one electrical cycle. For a synchronous generator with p magnetic poles and rotor speed n in revolutions per minute, f = pn/120. For example, four poles at 1,800 rpm produce 60 Hz.
Wavelength is a spatial distance, not a time interval. For a traveling wave, λ = vp/f, where vp is the propagation speed in the medium. On a voltage-versus-time graph, the spacing between repeated points is a period. It cannot be called a physical wavelength without a propagation-speed relationship. Electron drift speed is not the propagation speed of the electrical signal.
Technical background: [R1], [R6]. The frequency and period examples are direct calculations.
6. Instantaneous, peak, RMS, and average values
Instantaneous and peak values
An instantaneous value is the voltage or current at a particular moment. The peak value is the largest magnitude reached. For a symmetrical sine wave with no DC offset, the positive and negative peaks have equal magnitude. Peak-to-peak voltage is the difference between them.
v(t) = Vpk sin(2πft + θ0)
Vpp = 2Vpk Ipp = 2Ipk
Example: a 170 V peak sine wave has v = 170 sin 30° = 85.0 V at an electrical angle of 30°, and v = −85.0 V at 210°. Check whether your calculator expects degrees or radians.
RMS means heating-equivalent
The root-mean-square value produces the same average heating in a fixed resistor as the same numerical value of DC. For equally spaced samples, square each value, average those squares, and take the square root. For a repeating waveform, use samples covering complete cycles.
Vrms ≈ √[(v12 + v22 + … + vN2)/N]
Vrms = Vpk/√2 ≈ 0.7071Vpk
Irms = Ipk/√2 Vpk = √2 Vrms
The 0.7071 multiplier applies to a sine wave, not to every AC waveform. A symmetrical square wave with levels +1 A and −1 A has an RMS value of 1 A. A sine wave with a 1 A peak has an RMS value of 0.7071 A and produces half the heating of 1 A DC in the same resistor.
State exactly which average you mean
The signed average of a symmetrical sine wave over a complete cycle is zero: the positive and negative areas cancel. The average over the positive half-cycle is different. The average of the full-wave-rectified waveform, which takes the absolute value of each sample, has the same positive value as the positive-half-cycle average.
Vavg,cycle = 0
Vavg,+ = Vavg,rect = (2/π)Vpk ≈ 0.6366Vpk
The negative-half-cycle signed average is −0.6366Vpk. Apply the same relationships to sinusoidal current. The 0.6366 value is not RMS and is not the signed full-cycle average.
Worked conversions
| Given | Calculation | Result |
|---|---|---|
| Vrms = 120 V | Vpk = 120√2 | 169.71 V |
| Vrms = 120 V | Vpp = 2(120√2) | 339.41 V |
| Ipk = 30 A | Irms = 30/√2 | 21.21 A |
| Ipk = 30 A | Iavg,rect = 2(30)/π | 19.10 A |
Technical background: [R1]. Worked values were recalculated from the equations shown.
7. Phase, leading, and lagging
Phase compares the timing of signals at the same frequency. Two sine waves are in phase when corresponding peaks, troughs, and same-direction zero crossings occur together. Their amplitudes do not have to be equal. A wave that reaches the same point earlier leads; one that reaches it later lags.
Phase difference in degrees = 360° × Δt/T
At 60 Hz, a 4.17 ms shift is approximately 90°. A 180° shift reverses polarity; 360° is a whole-cycle shift and returns to the same phase. Equal-amplitude signals 180° apart sum to zero mathematically, but this is not permission to connect incompatible voltage sources in parallel.
For ideal elements under sinusoidal steady-state conditions, resistor current is in phase with its voltage, inductor current lags its voltage by 90°, and capacitor current leads its voltage by 90°. The memory aid ELI the ICE man uses E as an older symbol for voltage: E leads I in L; I leads E in C.
These are continuing waveforms, not a sequence in which a component waits a quarter-cycle before allowing any current. Real resistance combined with reactance usually produces a phase angle between 0° and 90° in magnitude.
Technical background: [R1].
8. Ohm’s law for a resistive AC circuit
For an ideal resistor, v(t) = i(t)R at each instant. The same proportionality works with RMS values or with peak values, provided the voltage and current values are of the same type.
I = V/R V = IR P = VI = I2R = V2/R
Consider 5 Ω and 15 Ω resistors in series across a 120 V RMS sine-wave source. Their total resistance is 20 Ω, so the RMS current is 6.00 A.
Ipk = √2(6.00) = 8.49 A
Iavg,rect = (2/π)(6√2) = 5.40 A
The signed full-cycle average remains 0 A, and real power is 120 × 6 = 720 W. Do not put the 5.40 A rectified-average current into the RMS heating formula and expect the correct power.
9. Inductance, self-induction, and coil losses
Inductance is a circuit property that relates changing current to magnetic flux linkage and induced voltage. Every current path has some inductance; coils are designed to make it useful. The unit is the henry (H). One henry produces a 1 V terminal voltage when current changes at 1 A/s under the reference convention below.
vL = L di/dt WL = ½Li2
The terminal-voltage equation uses the passive sign convention: current enters the terminal labeled positive. When the same effect is described as a counter-EMF opposing the change, it is often written eind = −L di/dt. These signs describe different voltage references, not conflicting physics.
For a 0.20 H ideal inductor whose current rises by 3 A in 0.010 s at a constant rate, the voltage magnitude is 0.20 × 3/0.010 = 60 V. At a current of 3 A, its stored magnetic energy is ½(0.20)(3)2 = 0.90 J.
Useful conversions are 1 mH = 10−3 H and 1 µH = 10−6 H. For a long, ideal solenoid, L ≈ μN2A/ℓ, where ℓ is the magnetic path length in this approximation. Increasing turn count, core permeability, or cross-sectional area generally increases L; increasing length generally reduces it. The simple proportionalities assume geometry and material conditions remain appropriate.
A real coil is not lossless. Its winding dissipates I2R heat. A magnetic core can also have hysteresis loss from changing magnetization and eddy-current loss from induced circulating currents. Winding resistance should be neglected only when the problem explicitly assumes an ideal inductor or when the approximation is justified.
Technical background: [R5].
10. Current growth and decay in an RL circuit
An ideal inductor’s current cannot jump instantly under a finite voltage. For a DC step applied to a series RL circuit initially carrying no current, the current approaches Vs/R. Here R means the total series resistance, including winding and source resistance when relevant.
τ = L/R Ifinal = Vs/R
i(t) = Ifinal[1 − e−t/τ]
vL(t) = Vse−t/τ vR(t) = Vs[1 − e−t/τ]
Immediately after the step, current and resistor voltage are zero, and the inductor has the source voltage across it. As current rises, resistor voltage rises and ideal inductor voltage falls.
For source-free decay through a closed resistive path, i(t) = I0e−t/τ. Use the resistance of the actual decay path: its time constant may differ from the charging path. Opening a wire is not equivalent to providing that controlled decay path.
After one time constant, growth reaches 63.2% of the final value. After five, it reaches 99.3%, not exactly 100%. A 10 A final current therefore rises to about 6.32 A at one time constant and 9.93 A at five.
A pure ideal inductor with zero resistance across a constant ideal DC voltage does not approach a finite final current. Instead, di/dt = V/L and current ramps. A real circuit’s resistance, saturation, source limits, and protection alter that behavior.
Technical background: [R8].
11. Mutual inductance and series-connected coils
Two coils are magnetically coupled when flux associated with current in one links the other. A changing current in one coil can then induce voltage in the second. Mutual inductance M is measured in henrys.
M = k√(L1L2) 0 ≤ k ≤ 1
The coefficient of coupling k describes the degree of magnetic coupling for the chosen linear model. It depends on the geometry, relative placement, and magnetic path. Treating it simply as the fraction of turns touched by flux can be misleading.
For L1 = 10 H, L2 = 20 H, and k = 0.50, M = 0.50√(10 × 20) = 7.07 H. Steady DC in the first coil produces no continuing induced voltage in the second after the field has settled; switching or changing the current produces a transient.
Without appreciable magnetic coupling, series inductances add. For two coupled inductors, the connection determines whether the mutual effects aid or oppose.
LT = L1 + L2 (negligible coupling)
LT = L1 + L2 ± 2M (two coupled coils)
Example: 10 H and 5 H coils with M = 7 H give 29 H when series-aiding and 1 H when series-opposing. The proposed M is physically consistent with the linear bound M ≤ √(10 × 5) = 7.071 H. Dot markings, together with current reference directions, identify the appropriate sign.
Technical background: [R9]. Series-equivalent values are derived from the coupled-coil voltage equations.
12. Electric fields and capacitance
An electric field exerts force on charge. Electrostatic field lines indicate the force direction on a positive test charge, from positive toward negative charge. In dielectrics, bound charges can shift or align slightly, producing polarization. Conductors redistribute charge and can shield electrostatic fields; a static electric field does not simply pass unchanged through every material.
A capacitor has two conductors separated by a dielectric. Charging moves charge onto one conductor and away from the other through the external circuit. In the ideal two-plate model, the plates carry +q and −q. Here q is the magnitude on either plate, not the sum of the two magnitudes.
q = Cv C = q/v iC = C dv/dt
Capacitance is measured in farads (F). A 1 F capacitor holds 1 C of charge magnitude on each plate at a 1 V difference. Common units are µF (10−6 F), nF (10−9 F), and pF (10−12 F).
For large parallel plates with a uniform dielectric and negligible edge effects:
C = ε0εrA/d WC = ½Cv2
A is the facing area of one plate in square meters; d is separation in meters; εr is relative permittivity; ε0 ≈ 8.854 × 10−12 F/m. More area or higher permittivity increases capacitance; more spacing decreases it. Relative permittivity is not dielectric strength: a higher dielectric constant does not automatically mean better insulation or a higher voltage rating.
With dimensions in inches, a useful equivalent is C in pF ≈ 0.2249εrA/d, where A is in square inches and d is in inches. For an assumed εr = 3.5, A = 12 in2, and d = 0.05 in, C ≈ 188.9 pF. That dielectric value is a problem assumption, not a specification for all paper products.
With finite current, an ideal capacitor’s voltage cannot jump. After a DC charging transient has settled, the ideal capacitor blocks steady conduction current. A changing electric field in its dielectric corresponds to displacement current; conduction electrons do not cross the ideal dielectric from plate to plate.
13. Real capacitors: ratings, construction, and losses
Real capacitors have leakage, equivalent series resistance (ESR), parasitic inductance, tolerances, and limits on temperature, voltage, ripple current, and service conditions. Their capacitance can also vary with temperature, bias, frequency, or age depending on construction. They are not perfectly constant, lossless components.
Do not choose a capacitor for AC service solely by multiplying the RMS voltage by 1.5. Although 500 V RMS sinusoidal voltage has a 707.1 V peak, a 750 V DC rating alone does not establish suitability for that AC duty. The capacitor must have an appropriate manufacturer-specified AC rating and meet the application’s current, frequency, thermal, transient, and safety requirements.
| Type or application | What to know |
|---|---|
| Aluminum electrolytic | Uses an oxide dielectric. Most types are polarized and must not be connected directly across reversing AC unless explicitly designed for that duty. |
| Film capacitor | Uses a plastic-film dielectric and foil or metallized electrodes. Many are nonpolarized; only appropriately rated versions are suitable for AC power service. |
| Motor-start capacitor | Must meet the motor manufacturer’s specified capacitance, AC rating, and intermittent-duty requirements. |
| Motor-run or power-factor capacitor | Must be specifically suitable for its continuous-duty AC application. Do not substitute by capacitance alone. |
| Variable capacitor | Allows intentional capacitance adjustment. It is different from the small unintentional variation of a nominally fixed capacitor. |
Self-healing is a construction-specific process, not permission to exceed ratings. Leakage and dielectric or ESR losses turn energy into heat. An ideal capacitor has zero average real-power loss in periodic steady state; a real one does not. A capacitor discharged through a resistor gives up stored energy, but that energy becomes resistor heat rather than being fully recovered for useful work.
Technical background and manufacturer examples: [R12], [R13]. Product selection must use the actual component data sheet.
14. RC charging, discharging, and the time constant
For a source step Vs applied through resistance R to an initially uncharged capacitor C, the time constant is τ = RC. Use ohms and farads to obtain seconds.
vC(t) = Vs[1 − e−t/τ]
i(t) = (Vs/R)e−t/τ vR(t) = Vse−t/τ
At the start, capacitor voltage is zero, charging current is Vs/R, and resistor voltage equals the source voltage. As charging progresses, capacitor voltage rises while current and resistor voltage fall. At every instant, vR + vC = Vs.
For discharge through R from an initial capacitor voltage V0, vC(t) = V0e−t/τ. The current magnitude is (V0/R)e−t/τ; its sign depends on the chosen reference direction. Use the resistance actually present in the discharge path.
The same normalized exponential curves describe capacitor voltage and inductor current. A universal chart does not determine τ by itself: first calculate RC or L/R, then read elapsed time as a multiple of that value.
| Elapsed time | Rise toward final value | Decay remaining |
|---|---|---|
| 1τ | 63.21% | 36.79% |
| 2τ | 86.47% | 13.53% |
| 3τ | 95.02% | 4.98% |
| 4τ | 98.17% | 1.83% |
| 5τ | 99.33% | 0.67% |
Example: R = 10 kΩ and C = 100 µF give τ = 1.00 s. With a 6 V source, capacitor voltage is 3.79 V at 1 s and 5.96 V at 5 s. During discharge from 6 V, it is about 0.0404 V after 5 s. These numerical examples do not establish a universal safe waiting time for real equipment.
15. Capacitors in series and parallel
Parallel capacitors share the same voltage. Their charges add, so their capacitances add. Series capacitors in the usual initially uncharged ideal arrangement carry the same charge magnitude, while their voltages add; their equivalent capacitance is therefore a reciprocal sum.
CT,parallel = C1 + C2 + … + Cn
1/CT,series = 1/C1 + 1/C2 + … + 1/Cn
For two in series: CT = C1C2/(C1 + C2)
For 10, 20, and 30 µF in series, 1/CT = 1/10 + 1/20 + 1/30, giving CT = 5.45 µF. For 0.03, 2.00, and 0.25 µF in parallel, CT = 2.28 µF. Using the same unit throughout is sufficient; conversion to farads is not necessary for these combination formulas.
Series connection does not physically move the plates inside each capacitor. It changes the relationship between total charge and applied voltage. In a real series bank, unequal leakage and tolerances affect voltage sharing; adding nameplate voltage ratings is not by itself a safe design method.
Technical background: [R15].
16. Inductive and capacitive reactance
Reactance is the frequency-dependent part of impedance associated with energy storage. Its unit is the ohm. Ideal inductive and capacitive reactances do not themselves represent average real-power dissipation.
XL = 2πfL XC = 1/(2πfC)
Use frequency in hertz, inductance in henrys, and capacitance in farads. At a fixed RMS voltage, increasing frequency increases ideal inductive reactance and reduces inductor current. Increasing frequency reduces ideal capacitive reactance and increases capacitor current.
Inductor example: pay attention to H versus mH
f = 60 Hz, L = 20 H
XL = 2π(60)(20) = 7,539.82 Ω ≈ 7.540 kΩ
Using the rough constant 2π ≈ 6.28 gives 7,536 Ω, not 7.536 Ω. A value near 7.54 Ω would instead correspond to 20 mH at 60 Hz. The prefix makes a factor-of-1,000 difference.
Capacitor example
f = 100 Hz, C = 50 µF = 50 × 10−6 F
XC = 1/[2π(100)(50 × 10−6)] = 31.83 Ω
For a sinusoidal voltage, iC = C dv/dt is greatest when voltage crosses zero and its slope is greatest. It is zero at a voltage peak, where the slope is zero. That is why ideal capacitor current leads voltage by 90°. The corresponding inductor relation vL = L di/dt gives current lagging voltage by 90°.
Technical background: [R1]. Examples are direct recalculations.
17. Net reactance in a series circuit
For series-connected ideal L and C, subtract capacitive reactance from inductive reactance and keep the sign.
X = XL − XC
A positive X means net inductive behavior; a negative X means net capacitive behavior. For XL = 50 Ω and XC = 25 Ω, X = +25 Ω. For XL = 10 Ω and XC = 20 Ω, X = −10 Ω. Do not silently change subtraction order to force a positive answer.
The following higher-frequency examples practice unit conversion. They are ideal-component calculations; real radio-frequency components may have important parasitic effects.
| Inputs | XL | XC | Signed X |
|---|---|---|---|
| 4 MHz; 100 µH; 0.001 µF | 2,513.27 Ω | 39.79 Ω | +2,473.49 Ω, inductive |
| 1 MHz; 100 µH; 0.0002 µF | 628.32 Ω | 795.77 Ω | −167.46 Ω, capacitive |
Convert 0.001 µF to 1.0 × 10−9 F and 0.0002 µF to 2.0 × 10−10 F before calculating XC.
Technical background: [R16].
18. Impedance and Ohm’s law for AC
Impedance combines resistance and reactance. With j denoting the imaginary unit (j2 = −1), a series-equivalent impedance is Z = R + jX. Its magnitude, written |Z|, is a nonnegative number measured in ohms.
Z = R + j(XL − XC)
|Z| = √[R2 + (XL − XC)2]
I = V/|Z| φ = atan2(X, R)
Here φ is voltage phase minus current phase. For positive R, φ > 0 means current lags; φ < 0 means current leads. The function atan2 keeps the correct quadrant. In phasor form, Ohm’s law is Ṽ = ĨZ; use RMS magnitudes consistently when calculating power.
Resistance and reactance are perpendicular components in this representation. They are not opposing forces, and they are not added as ordinary positive numbers. Kirchhoff’s laws still apply; AC steady-state voltages and currents are added as phasors rather than as unrelated magnitudes.
Worked impedance and voltage/current examples
| Given series values | Calculation | Result |
|---|---|---|
| R = 8 Ω; XL = 5 Ω | |Z| = √(82 + 52) | 9.43 Ω |
| R = 40 Ω; XL = 10 Ω; XC = 20 Ω | X = −10 Ω; |Z| = √(402 + 102) | 41.23 Ω, capacitive |
| V = 50 V; R = 5 Ω; XL = 25 Ω; XC = 15 Ω | |Z| = √(52 + 102); I = 50/|Z| | 4.47 A, lagging |
| I = 5 A; R = 5 Ω; XL = 15 Ω; XC = 10 Ω | |Z| = √(52 + 52); V = 5|Z| | 35.36 V RMS |
Use the square-root formula directly only when R and X are the series-equivalent components of the same impedance. A resistor in one parallel branch is not automatically that series-equivalent R.
Technical background: [R16].
19. Real, reactive, and apparent power
Instantaneous power is p(t) = v(t)i(t). With the passive sign convention, positive instantaneous power means a component absorbs energy; negative instantaneous power means it returns energy. An ideal resistor continually converts energy to heat. Ideal inductors and capacitors alternately store and return energy.
For sinusoidal steady-state voltage and current, the three power quantities are:
P = VI cos φ in watts (W)
Q = VI sin φ in volt-amperes reactive (var)
S = VI = √(P2 + Q2) in volt-amperes (VA)
Real power P is average energy conversion per second. Reactive power Q characterizes the out-of-phase energy exchange; it is positive for an inductive load and negative for a capacitive load under this convention. Apparent power S is the product of RMS voltage and RMS current and is nonnegative. Complex power is P + jQ; S is its magnitude.
For a series-equivalent circuit, P = I2R, Q = I2X, and S = I2|Z|. For a resistor branch, use the current through that resistor. For separate ideal L and C branches, calculate their powers separately and add Q algebraically.
QL = IL2XL QC = −IC2XC
The difference S − P is not reactive power and is not simply wasted power. Real losses, such as conductor heating, belong to P. Reactive current can nevertheless increase those real losses by increasing RMS current in the supply system.
Worked example: a net-capacitive series load
Given V = 500 V RMS, R = 60 Ω, XL = 30 Ω, and XC = 110 Ω:
X = 30 − 110 = −80 Ω
|Z| = √(602 + 802) = 100 Ω I = 500/100 = 5 A
P = 52(60) = 1,500 W
Q = 52(−80) = −2,000 var
S = 500(5) = 2,500 VA
The capacitor’s reactive contribution is −2,750 var; the inductor’s is +750 var. Their sum is −2,000 var. Describing the magnitude as 2,000 var capacitive is also acceptable when the type is explicitly stated.
Technical background: [R7], [R16]. Power-triangle values are direct calculations.
20. Power factor and practical correction
Power factor is real power divided by apparent power. For the sinusoidal linear-load model, it also equals the cosine of the voltage-current phase difference.
PF = P/S and, for sinusoidal waveforms, PF = cos φ
The previous example has PF = 1,500/2,500 = 0.60 leading. A series-equivalent circuit also has PF = R/|Z|. Always distinguish leading from lagging; a positive PF number alone does not tell you whether the load is inductive or capacitive.
For distorted current or voltage, PF = P/(VrmsIrms) still defines true power factor, but cos φ alone generally does not. Harmonic distortion and phase displacement must not be confused.
What a correction capacitor does
An appropriately engineered capacitor bank is normally connected in parallel with an inductive load or supply bus. Its reactive current offsets some of the load’s reactive-current demand at the source. At the same voltage and real load power, this can reduce source current, conductor losses, and required apparent-power capacity. The load still needs its internal magnetic field; correction does not remove that requirement.
For a single-phase sinusoidal inductive load, improving a lagging power factor to a higher lagging value (or unity) requires this magnitude of capacitive correction:
Qc,required = P[tan(cos−1PFold) − tan(cos−1PFtarget)]
C = Qc,required/(2πfV2)
Example: a 10.0 kW inductive load at 240 V RMS and 60 Hz is corrected from PF = 0.80 to PF = 0.95, both lagging. The ideal calculation gives Qc,required = 4.213 kvar and C = 194.0 µF. Source current falls from 52.08 A to 43.86 A. The capacitor contributes a negative Q of that magnitude.
This is an analysis example, not a capacitor-bank specification. Real designs consider harmonics, resonance, variable load, switching transients, discharge, protection, and equipment instructions. Do not place correction capacitors on a drive output unless the equipment manufacturer explicitly permits the arrangement. Adding series reactance to cancel a load is not an interchangeable substitute for shunt correction: it can change load current and operating power substantially.
Technical background and application limitations: [R7], [R17], [R18].
21. Complete series-RLC example
Use a 110 V RMS, 60 Hz source with R = 4 Ω, L = 27 mH, and C = 380 µF in series. The same current flows through all three components. These are nominal problem values; no component tolerances are specified.
Step 1: convert the units and calculate reactance
L = 0.027 H C = 0.000380 F
XL = 2π(60)(0.027) = 10.178760 Ω
XC = 1/[2π(60)(0.000380)] = 6.980480 Ω
X = XL − XC = +3.198280 Ω
Step 2: calculate impedance and current
|Z| = √(42 + 3.1982802) = 5.121425 Ω
I = 110/|Z| = 21.478396 A ≈ 21.48 A
Step 3: calculate power and phase
| Quantity | Calculation | Result |
|---|---|---|
| Real power | P = I2R | 1,845.29 W |
| Reactive power | Q = I2X | +1,475.44 var |
| Apparent power | S = VI | 2,362.62 VA |
| Power factor | PF = R/|Z| = P/S | 0.7810 lagging |
| Phase difference | φ = atan2(X,R) | +38.64° |
Step 4: check the component voltages
VR = IR = 85.91 V VL = IXL = 218.62 V
VC = IXC = 149.93 V
Use the phasor check V = √[VR2 + (VL − VC)2], which returns 110 V with unrounded inputs. A reactive component voltage can exceed the source voltage because the component voltages are not all in phase. Actual components must be selected for their own stresses, not just for the source RMS voltage.
Why the older 22 A answer differs: Rounding XL to 10 Ω and XC to 7 Ω before continuing produces X = 3 Ω, |Z| = 5 Ω, I = 22 A, P = 1,936 W, Q = 1,452 var, S = 2,420 VA, and PF = 0.80. That is a consistent coarse teaching approximation, but it is not the full-precision solution of the stated L and C. Do not mix values from the two methods.
Technical background: [R16]. All values above were recalculated from the stated circuit.
22. Complete parallel-RLC example
For separate ideal R, L, and C branches in parallel, voltage is common to all branches. Take the source voltage as the 0° reference. Resistor current is in phase, inductor current is at −90°, and capacitor current is at +90°.
IR = V/R IL = V/XL IC = V/XC
Ĩ = IR + j(IC − IL)
I = √[IR2 + (IC − IL)2] |Z| = V/I
These formulas apply to the illustrated separate ideal branches. For a branch containing both resistance and reactance, calculate that branch’s complex current first and then sum all branch currents.
Step 1: solve the branch currents
Given V = 300 V RMS, R = 100 Ω, XL = 50 Ω, and XC = 150 Ω at the operating frequency:
IR = 300/100 = 3 A IL = 300/50 = 6 A
IC = 300/150 = 2 A
Step 2: sum as phasors
Ĩ = 3 + j(2 − 6) = 3 − j4 A
I = √(32 + 42) = 5 A |Z| = 300/5 = 60 Ω
The current angle is −53.13°, so current lags the voltage. The 6 A inductor branch current can exceed the 5 A source-current magnitude because the 2 A capacitive branch current partially cancels it at the source.
Step 3: calculate power
P = V2/R = 3002/100 = 900 W
Q = V2/XL − V2/XC = 1,800 − 600 = +1,200 var
S = VI = 300(5) = 1,500 VA
PF = P/S = 900/1,500 = 0.60 lagging
The power-triangle check is √(9002 + 1,2002) = 1,500 VA. Notice that real power is measured in W, not Ω.
Do not confuse two different equivalent reactances
The complete circuit’s complex impedance is:
Z = 300/(3 − j4) = 36 + j48 Ω
Thus its series-equivalent resistance is 36 Ω and its series-equivalent reactance is +48 Ω. The L-and-C-only parallel combination has an equivalent inductive reactance of 300/(6 − 2) = 75 Ω. That 75 Ω is the equivalent reactive branch, not the imaginary part of the complete circuit’s impedance.
Using PF = R/|Z| with the original 100 Ω resistor branch would be wrong. Use P/S, IR/I for this ideal arrangement, or the correct series-equivalent resistance 36 Ω divided by 60 Ω.
When finding impedance of a linear circuit whose source voltage is unspecified, any nonzero test voltage may be used consistently. With 50 V here, branch currents are 0.500 A, 1.000 A, and 0.3333 A; the total magnitude is 0.8333 A and |Z| is still 60 Ω. Those test currents are not the actual currents at 300 V.
Technical background: [R1], [R16]. The parallel results follow Kirchhoff’s current law and complex arithmetic.
23. Resonance and the limits of the simple model
In an ideal series RLC circuit, resonance occurs when XL = XC. Net series reactance is then zero and the impedance equals R. At a fixed source voltage, the series current is maximum and source power factor is unity, even though L and C can each store substantial energy.
f0 = 1/(2π√LC)
For L = 27 mH and C = 380 µF, the ideal resonant frequency is about 49.69 Hz. That is below the 60 Hz operating frequency, consistent with the net-inductive result in the worked example.
For ideal separate parallel L and C branches, the same frequency makes their susceptances cancel. With a resistor also in parallel, the source sees that resistor at resonance, but reactive branch currents can still circulate. Real winding resistance, parasitic effects, nonlinear behavior, and supply impedance change the resonance and its severity.
Resonance is not always desirable. It can magnify voltage or current, particularly in networks with harmonics. Do not treat the simple formula as a complete equipment design or a universal instruction to cancel every reactance.
24. Formula and unit reference
| Quantity | Relationship | Important condition |
|---|---|---|
| Period | T = 1/f | T in s; f in Hz. |
| Sine-wave RMS | Vrms = Vpk/√2 | Not a universal waveform multiplier. |
| Rectified sine mean | Vavg,rect = 2Vpk/π | Signed full-cycle sine mean is zero. |
| Inductive reactance | XL = 2πfL | L in H; result in Ω. |
| Capacitive reactance | XC = 1/(2πfC) | C in F; result in Ω. |
| Series impedance | |Z| = √[R2 + (XL − XC)2] | Use series-equivalent R and X. |
| Real power | P = VI cos φ | RMS V and I; sine-wave model; W. |
| Reactive power | Q = VI sin φ | Positive inductive, negative capacitive; var. |
| Apparent power | S = VI | RMS V and I; VA. |
| Power factor | PF = P/S | Also cos φ only under the stated sinusoidal conditions. |
| RC time constant | τ = RC | R in Ω; C in F; τ in s. |
| RL time constant | τ = L/R | Use total resistance of the actual path. |
Use V for volts, A for amperes, Ω for ohms, W for watts, VA for volt-amperes, var for reactive power, H for henrys, F for farads, Hz for hertz, and J for stored energy. Prefixes are k = 103, m = 10−3, µ = 10−6, n = 10−9, and p = 10−12.
Knowledge check
| No. | Question | Answer |
|---|---|---|
| 1 | What is the signed full-cycle mean of a 100 V peak sine wave? | 0 V. |
| 2 | What are its RMS and rectified-average values? | 70.71 V RMS; 63.66 V rectified mean. |
| 3 | Does ideal capacitor current lead or lag its voltage? | It leads by 90° in sinusoidal steady state. |
| 4 | What is XL for 20 mH at 60 Hz? | 7.54 Ω, not 7.54 kΩ. |
| 5 | What fraction of initial capacitor voltage remains after 5τ? | About 0.67%; it is not exactly zero. |
| 6 | A series circuit has R = 6 Ω, XL = 13 Ω, XC = 5 Ω, V = 100 V. Find I and PF. | X = 8 Ω; |Z| = 10 Ω; I = 10 A; PF = 0.60 lagging. |
| 7 | Does S − P equal wasted power? | No. Use the power definitions and actual real-loss calculations. |
| 8 | Can a DC voltage rating alone establish suitability for reversing AC? | No. Use the manufacturer’s AC and application ratings. |
Technical references
The explanatory text and diagrams in this replacement are newly prepared. These references were used to check physical relationships and application limitations; no publisher diagrams are reproduced. OpenStax references are to University Physics Volume 2 by Samuel J. Ling, William Moebs, and Jeff Sanny. Sources accessed September 8, 2026.
[R1] OpenStax, University Physics Volume 2, 15.2: Simple AC Circuits
[R2] OpenStax, University Physics Volume 2, 15.6: Transformers
[R4] OpenStax, 12.2: Magnetic Field Due to a Thin Straight Wire
[R4a] OpenStax, 12.3: Magnetic Force between Two Parallel Currents
[R4b] OpenStax, 12.6: Solenoids and Toroids
[R5] OpenStax, 14.2: Self-Inductance and Inductors
[R6] OpenStax, 13.1: Faraday’s Law
[R6a] OpenStax, 13.6: Electric Generators and Back Emf
[R7] OpenStax, 15.4: Power in an AC Circuit
[R8] OpenStax, 14.4: RL Circuits
[R9] OpenStax, 14.1: Mutual Inductance
[R10] OpenStax, 8.1: Capacitors and Capacitance
[R11] OpenStax, 8.4: Capacitor with a Dielectric
[R12] TDK Electronics: Film-Capacitor Calculation and Selection Tool (application-rating parameters)
[R13] Nichicon: UCN Series Release (aluminum-oxide dielectric construction, April 9, 2025)
[R14] OpenStax, 10.5: RC Circuits
[R15] OpenStax, 8.2: Capacitors in Series and in Parallel
[R16] OpenStax, 15.3: RLC Series Circuits with AC
[R17] Schneider Electric: VarSet Detuned Capacitor Banks (reactive-power compensation)
[R18] Schneider Electric: Guidance on Power-Factor Correction Capacitors with Variable-Frequency Drives
[R19] OpenStax, 15.5: Resonance in an AC Circuit
Lesson replaced: Pass ICC Exam: Basic AC Theory. Its topic scope and principal circuit givens informed this replacement. This is not a certification or endorsement by a source publisher, ICC, or a standards body.