ICC 550 Kansas Standard General Building Contractor (A) Exam Quiz Welcome to your free ICC 550 Kansas Standard General Building Contractor (A) Exam Quiz REQUIRED - Enter your email address to receive a printable copy of your test results. 1. In a Type IA building, what is the required fire-resistance rating for the primary structural frame? 1 hour 2 hours 3 hours 4 hours None 2. For a standard fire wall with a 2-hour fire-resistance rating, what is the minimum required distance the fire wall must extend above the roof? 18 inches 30 inches 36 inches 48 inches None 3. What is the standard required height of handrails, measured vertically from the stair tread nosing? 30 to 34 inches 34 to 38 inches 36 to 42 inches 42 inches minimum None 4. An assembly room used for food and drink consumption with an occupant load of less than 50 persons is classified as which Occupancy Group? Group A-2 Group A-3 Group B Group M None 5. The structural design wind pressures for a building are determined using which standard referenced in the IBC? ASCE 7 ACI 318 ASTM E119 NFPA 13 None 6. For a standard fire wall with a 2-hour fire-resistance rating, what is the minimum required distance the fire wall must extend above the roof? 18 inches 30 inches 36 inches 48 inches None 7. Unless specifically exempted, what is the minimum width of a means of egress corridor serving an occupant load of 50 or more? 36 inches 44 inches 48 inches 60 inches None 8. Treated wood or naturally durable wood must be used for wood joists or the bottom of a wood structural floor when they are closer than how many inches to the exposed ground? 12 inches 18 inches 24 inches 30 inches None 9. What is the occupancy classification for a hospital? Group A-3 Group B Group I-2 Group R-1 None 10. What is the maximum horizontally dimensioned spacing for fireblocking in concealed spaces of stud walls and partitions? 10 feet 12 feet 16 feet Fireblocking is only required vertically. None 11. A building permit is NOT required for a one-story detached accessory structure used as a tool or storage shed, provided the floor area does not exceed how many square feet? 100 sq. ft. 120 sq. ft. 150 sq. ft. 200 sq. ft. None 12. What is the minimum required thickness of a concrete floor slab supported directly on the ground? 3 inches 3.5 inches 4 inches 5 inches None 13. What is the minimum uniform live load required for the floor design of an office building? 40 psf 50 psf 80 psf 100 psf None 14. For standard commercial stairways, what is the maximum allowable riser height? 7 inches 7.75 inches 8 inches 8.25 inches None 15. Asphalt shingles shall only be used on roof slopes of not less than: 1/4 unit vertical in 12 units horizontal 1 unit vertical in 12 units horizontal 2 units vertical in 12 units horizontal 3 units vertical in 12 units horizontal None 16. The maximum slope of a ramp used as part of a means of egress is: 1 unit vertical in 8 units horizontal (1:8) 1 unit vertical in 10 units horizontal (1:10) 1 unit vertical in 12 units horizontal (1:12) 1 unit vertical in 15 units horizontal (1:15) None 17. Glazing in fixed panels adjacent to a door requires safety glazing if the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position, UNLESS the bottom exposed edge of the glazing is greater than how many inches above the floor? 18 inches 24 inches 36 inches 60 inches None 18. What is the minimum depth of a shallow foundation (footing) below the undisturbed ground surface? 6 inches 12 inches 18 inches 24 inches None 19. Buildings constructed entirely of noncombustible materials are classified as which Construction Types? Types I and II Types III and IV Type V All types None 20. In general, what is the minimum required ceiling height for occupiable spaces? 7 feet 0 inches 7 feet 6 inches 8 feet 0 inches 8 feet 6 inches None Prove you are human Time is Up!