Pass ICC F27 National Standards Master Plumber with Gas Exam

Learn how to become an ICC F27 Master Plumber with Gas (Online and self-paced)

If your state, county, or city licensing agency requires you to pass the ICC F27 Master Plumber with Gas Exam, complete our online exam preparation course, then schedule your F27 exam through Pearson|VUE.

 

$199.00

* Shipping fees apply for the options not fully online.

Pass the ICC F27 Master Plumber with Gas Exam

Refresh your 2015 IPC & 2015 IFGC Code knowledge, successfully pass your ICC F27 Master Plumber with Gas Exam. Preparing for your ICC F27 exam has never been easier! You will pass the ICC F27 exam. We guarantee it!

Your Blueprint for Success. Pass the ICC F27 Exam, Guaranteed!

Refresh your 2015 IPC and 2015 IFGC code knowledge. Successfully prepare for your ICC F27 certification exam without leaving the comfort of your home or office. Our ICC F27 National Standard Master Plumber with Gas exam preparation course is your best, most affordable path to success!

Pass your ICC F27 Master Plumber With Gas exam. Our 100% money-back guarantee backs this course. We provide the study materials (excluding codebooks) required to PASS THE ICC F27 EXAM. 


How To Use Our Online Study Center

STUDY our “Navigating the 2015 IPCA Code Primer – This eManual will familiarize you with the code’s structure within the 15 chapters of the 2015 IPC. International Plumbing Code.

STUDY our “Navigating the 2015 IFGCA Code Primer – This eManual will familiarize you with the use, layout, and content of chapters 1 through 8 of the 2015 IFGC.

PRACTICE answering realistic exam questions using the methods explained in our “Navigating the 2015 IPC” and “Navigating the 2015 IFGC.” Over 1,500 code-specific practice questions and answers and unlimited full-length, timed final exams. 

The course includes:

  • eManual (Navigating the 2015 IPC. A Code Primer)
  • eManual (Navigating the 2015 IFGC. A Code Primer)
  • Printable Worksheets (Companion to 2015 IPC and IFGC eManuals)
  • Online Practice Questions (Practice looking up answers in your codebook, take full length simulated exams)

eManual – NAVIGATING THE 2015 IPC: A Code Primer:

Our “NAVIGATING THE 2015 IPC” eManuals help students review the (IPC) International Plumbing Code.
When you master the code, you master your Exam!

This eManual is the starting point for the TLC Certification Training Program. It will familiarize you with the use, layout, and content of chapters 1 through 15 of the 2015 IPC.

Manual includes:

  • The purpose and layout of the code
  • How to navigate the IPC
  • Codebook navigation exercises, speed drills
  • Using the Table of Contents
  • Breaking down questions by subject (Chapters 1-15)
    • Keyword Identification, how to Identify the subject of a question for easy reference.
    • How to search for a code article by referencing the INDEX
    • Code reference example questions with in-depth solutions.

You are allowed by ICC to use the 2015 IPC codebook when taking your ICC F27 Exam!


eManual  NAVIGATING THE 2015 IFGC: A Code Primer:

Our “NAVIGATING THE IFGC” eManual helps students review the (IFGC) International Fuel Gas Code. It will familiarize you with the use, layout, and content of chapters 1 through 8 of the 2015 IFGC.

eManual Includes

  • The purpose and layout of the code
  • How to navigate the IFGC
  • Codebook navigation exercises, speed drills
  • Using the Table of Contents
  • Breaking down questions by subject (Chapters 1-8)
    • Keyword Identification, how to Identify the subject of a problem for easy reference.
    • How to search for a code article by referencing the INDEX
    • Code reference example questions with in-depth solutions.

You are allowed by ICC to use the 2015 IFGC codebook when taking your ICC F27 Exam!


Online – STUDY QUESTIONS & PRACTICE EXAMS

Access eManuals, Study Questions, and Simulated Exams From Any Device With Internet Access!

Our online practice questions provide you with a framework to practice utilizing your 2015 IPC and 2015 IFGC Codebooks. The process of constantly utilizing your codebook to answer test questions builds up your speed and code knowledge. Our course provides you with the required skill set to pass your ICC F27 Master Plumber With Gas exam.

Four modes of study!

  • Chapter Study Mode: Covers over 1,500 ICC F27 exam practice questions & answers. (Organized as Question – Answer – Code Location)
  • Flashcard Mode: Online Virtual Flashcards provide randomized access to our entire question set and are an ideal setting to practice answering exam questions. (Organized as Question – Answer – Code Location)
  • Chapter Tests: Provides real-time feedback on each chapter of our study materials, enabling you to concentrate on chapters that need improvement.
  • Simulated Final Exams: Simulates the taking of your ICC F27 Master Plumber With Gas exam.
    • Full length (Exact  number of questions as on F27 Exam)
    • Timed (Exact amount of time as actual ICC F27 exam)
    • Randomized (Questions are randomized, all exams are unique)
    • Properly Balanced (Balanced according to the ICC Exam schedule guaranteeing a realistic ICC F27 exam simulation)

Take as many simulated final exams as you want! (These exams help you to gain the knowledge, speed, and confidence needed to pass your ICC F27 exam effortlessly)


One-year online access: Full access membership to our online study center. Experience the convenience of learning at home or in the office, saving valuable travel time to an in-person course.


THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2015 (IPC) INTERNATIONAL PLUMBING CODE AND (IFGC) INTERNATIONAL FUEL AND GAS CODE. IF YOU DO NOT POSSESS COPIES OF THESE CODEBOOKS, PURCHASE THEM BELOW.

ICC F27 Exam Breakdown

When performing plumbing work in a city, county, or state that requires ICC F27 Master Plumber With Gas certification, that jurisdiction requires you to take and pass the ICC F27 examination based on the International Plumbing Code.

You are allowed to use a copy of the 2015 IPC & IFGC when taking your F27 exam.

100 QUESTIONS – 4 HOUR TIME LIMIT – OPEN BOOK EXAM – 70% + TO PASS

  • Administration 4%
  • General Regulations 8%
  • Fixtures 5%
  • Water Heaters 4%
  • Water Supply & Distributions 11%
  • Sanitary Drainage 9%
  • Vents 13%
  • Traps, Interceptors, & Separators 4%
  • Storm Drainage 2%
  • Plan Reading 21%
  • Gas 19%

Please click the following link to read/download the ICC Candidate Information Bulletin.

This bulletin answers most questions raised by examination candidates. Please read it carefully. You will find it a useful reference throughout your registration and examination process.

Take Your ICC F27 Exam With Pearson|VUE

Schedule the exam at your closest Pearson|VUE testing center, then submit your results to the appropriate licensing agency immediately upon passing the exam.

Take your ICC F27 Exam at the Closest Pearson|VUE Test Center

ICC exams are available at Pearson|VUE testing centers across the country.
CLICK HERE – For more information or to set up an exam with Pearson|VUE. 


About the ICC F27 National Standard Master Plumber with Gas exam.

This information regarding the ICC F27 exam is provided to you as a courtesy. Check with ICC at www.iccsafe.org and/or Pearson|VUE at www.pearsonvue.com/icc to verify this information’s accuracy.

  • Contact the appropriate building department for specific licensing requirements.
  • Passing an ICC national standard exam is NOT a license to practice and does not guarantee a license in any jurisdiction.
  • To acquire a license to practice, you must apply to the specific state licensing agency or building department and meet all of their licensing requirements.

Pearson|VUE requirements/recommendations for scheduling the F27 exam.

IMPORTANT: ICC has been split into different testing programs on their website. You will need to know the three-digit exam code before registering for your Contractor/Trades exam. Each testing program will require a unique username and password.

The Contractor/Trades program is also split into exams that require pre-authorization and exams that do not require pre-authorization. View the current exams that require pre-authorization OR do not require pre-authorization.


To create an account, schedule an exam, view exams, or find a test center, please go to home.pearsonvue.com/icc/license.

2015 IPC Softcover
Required Codebook (Sold Separately) $91.75

The (IPC®) International Plumbing Code® provides minimum regulations for plumbing facilities in terms of both performance & prescriptive objectives & provides for the acceptance of new & innovative products, materials, & systems.


THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2015 (IPC). IF YOU DO NOT OWN A COPY OF THIS CODEBOOK, PURCHASE ONE IMMEDIATELY.

 

 

2015 IPC FAST-TABS
Codebook Navigation Aid (Sold Separately) $13.45

Tab your Codebook. Fast-Tabs help you navigate the 2015 IPC quickly and efficiently. Fast-tabs are a must-have item for IPC users and can dramatically lower the time spent searching through the codebook.


You can use our IPC Code Fast-Tabs when taking your F27 Exam!

Add the 2015 IFGC SOFTCOVER
Required Codebook (Sold Separately) $91.75

The scope of the (IFGC®) International Fuel Gas Code® addresses the design and installation of fuel gas systems and gas-fired appliances through prescriptive and performance requirements.


THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2015 (IFGC). IF YOU DO NOT OWN A COPY OF THIS CODEBOOK, PURCHASE ONE IMMEDIATELY.

2015 IFGC TURBO-TABS
Codebook Navigation Aid (Sold Separately) $17.50

Tab your Codebook. Fast-Tabs help you navigate the 2015 IFGC quickly and efficiently. Fast-tabs are a must-have item for IFGC users and can dramatically lower the time spent searching through the codebook.


You can use our IFGC Code Fast-Tabs when taking your F27 Exam!

Take our Free ICC F27 Master Plumber With Gas Exam

Pass this 20 question free F27 Master Plumber with Gas test, learn where you stand! These free F27 Plumber practice questions, based on the 2015 IPC & 2015 IFGC, are similar to those on the ICC F27 exam.

 

  • If you answer sixteen or more of these free ICC F27 practice questions correctly, you are in pretty good shape.
  • However, if you miss four or more questions, get this course, you are in danger of failing your ICC F27 exam.

An existing plumbing system that is __________ must be brought into compliance with the International Plumbing Code (IPC).

Correct! Wrong!

What is the term for a valve made to permit air to enter a plumbing drainage system one-way, when the pressure in the piping system becomes negative? The valve must seal the vent terminal at zero pressure by gravity and when the internal pressure is positive. The purpose of such a valve is to let air go into a system so that there is no need for a vent to extend to open air, and to keep sewer gases out of a building.

Correct! Wrong!

If the waste line is __________ , a domestic dishwashing machine waste line is allowed to discharge into a wye-branch fitting on the tailpiece of a kitchen sink.

Correct! Wrong!

Inspection for underground piping must be made before any ____________ is put in place, but after ditches or trenches are excavated and bedded, and piping is installed.

Correct! Wrong!

If a hot water storage tank or storage tank-type water heater is installed where leakage from the tank will cause damage, it must be installed in a galvanized steel pan made of metal at least ___________ gauge (0.0236 inch or 0.6010 mm) thickness, or other such pans that are approved for this purpose.

Correct! Wrong!

A clearance of __________ inches or more is required in front of an appliance, when outdoor combustion air is provided through a single opening.

Correct! Wrong!

If the manufacturer’s instructions allow the usage, what is the maximum distance in developed length allowed from fixture outlet to the inlet of a grease interceptor serving as a trap?

Correct! Wrong!

Where gravity flow cannot be used to discharge building sub drains to the sewer, then a tightly covered and vented ____________ with automatic pumping equipment or other approved methods to lift liquid and discharge it into the building gravity drainage system will be used. Unless it is in an existing structure, this system may not receive any drainage that is able to be discharged into the building sewer by gravity.

Correct! Wrong!

Piping supports for plumbing must be designed and installed in accordance with the ___________ seismic force provisions where earthquake loads are applicable in relation to building codes.

Correct! Wrong!

If the code requirements and the installation instructions from the manufacturer conflict, then the requirements that are __________ are applicable.

Correct! Wrong!

If a storage water heater operates ___________, it must have an approved self-closing (levered) pressure relief valve and temperature relief valve or combination valve that conforms to ANSI Z21.22-2006. The relief valve may not be used to control thermal expansion.

Correct! Wrong!

Permanent openings for natural ventilation in a garage where hydrogen-generating appliances are locate must have a free area of at least __________ square foot per 1,000 cubic feet of volume in the garage.

Correct! Wrong!

How much projected roof area is a 4-inch horizontal pipe with a 2-percent slope able to drain in a 3-inch rainfall area?

Correct! Wrong!

What is the proper name for a distance of 8 feet (2438 mm) or more in vertical developed length between connections of a drainage stack to horizontal branches? The measurement begins at the highest horizontal branch connection, and then down the stack.

Correct! Wrong!

Return air for a forced air furnace should not generally be taken from a __________.

Correct! Wrong!

The Chapter 13 provisions cover the design, materials, construction, and installation of __________ systems for collection, storage, treatment, and distribution, in accordance with the local jurisdiction’s laws, rules, and ordinances.

Correct! Wrong!

Except in engineered systems, a single wall chimney connector must have a horizontal length of no more than __________ the height of the vent or chimney.

Correct! Wrong!

What kind of fittings must be recessed drainage type?

Correct! Wrong!

Hangers for 3/4-inch nominal diameter carbon steel pipe being sued to supply natural gas to an appliance must not be more than ____________ feet apart.

Correct! Wrong!

Subsoil drains must be at least __________ in diameter. If a building is subject to backwater, then the subsoil drain must be protected by a backwater valve that is accessibly located. Subsoil drains may discharge to a drain, dry well, sump, trapped area, or above-ground approved location.

Correct! Wrong!