2021 ICC P1 Residential Plumbing Inspector Exam Quiz Welcome to your free 2021 ICC P1 Residential Plumbing Inspector Exam Quiz REQUIRED - Enter your email address and receive a printable copy of your test results. 1. A cleanout must be installed at the base of every: Fixture drain Trap arm Branch interval Drainage stack None 2. Slip joints are permitted to be used in residential plumbing systems ONLY on the: Trap outlet, trap seal, or within the trap seal Vents located in concealed spaces Horizontal branch drains inside a wall Water service line underground None 3. When an Air Admittance Valve (AAV) is used to vent a fixture, it must be installed a minimum of ________ above the horizontal branch drain or fixture drain being vented. 2 inches 4 inches 6 inches 12 inches None 4. To protect against cross-connection, all outdoor hose bibbs must be equipped with a: Gate valve Check valve Pressure-relief valve Vacuum breaker None 5. Every building must have at least one main vent that extends to the outdoors. The vent terminal must extend at least ________ above the roof. 6 inches 12 inches 18 inches 24 inches None 6. Standard fixture traps must have a liquid seal depth of not less than ________ and not more than ________. 1 inch ; 3 inches 2 inches ; 4 inches 3 inches ; 6 inches 4 inches ; 8 inches None 7. The discharge tube from a water heater temperature and pressure (T&P) relief valve must terminate no more than ________ above the floor or waste receptor. 2 inches 6 inches 12 inches 18 inches None 8. The standpipe serving a clothes washer must extend a minimum of ________ and a maximum of ________ above the trap weir. 12 inches ; 36 inches 18 inches ; 42 inches 24 inches ; 48 inches 18 inches ; 48 inches None 9. For horizontal drainage piping that is 2.5 inches in diameter or smaller, what is the minimum required uniform slope? 1/16 inch per foot 1/8 inch per foot 1/4 inch per foot 1/2 inch per foot None 10. Water service pipe shall be installed not less than ________ deep, or not less than 6 inches below the frost line, whichever is greater. 6 inches 12 inches 18 inches 24 inches None 11. If a pipe passes through a framing member and the hole is within ________ of the exposed edge of the member, a steel shield plate must be installed to protect the pipe from screws and nails. 1 inch 1.25 inches 1.5 inches 2 inches None 12. What is the maximum allowable distance between cleanouts on a horizontal drain line? 50 feet 75 feet 100 feet 125 feet None 13. If a vent pipe terminates outside, it must be located at least ________ horizontally from any openable window or door, unless it is at least 3 feet above the opening. 3 feet 5 feet 10 feet 12 feet None 14. A 1.5-inch fixture drain (trap arm) has a maximum allowable distance from the trap weir to the vent fitting of: 4 feet 5 feet 6 feet 8 feet None 15. What is the minimum required interior cross-sectional area for a standard residential shower compartment? 600 square inches 800 square inches 900 square inches 1,024 square inches None 16. What is the minimum required diameter for a residential water service pipe supplying a dwelling? 1/2 inch 3/4 inch 1 inch 1-1/4 inches None 17. When installing horizontal PVC piping for plumbing drainage, what is the maximum allowable distance between supports? 3 feet 4 feet 6 feet 8 feet None 18. If a water heater is installed in a location where a leak could cause structural damage, a galvanized steel or plastic drain pan must be installed. The drain pipe from this pan must have a minimum inner diameter of: 1/2 inch 3/4 inch 1 inch 1-1/4 inches None 19. A water closet must have a minimum clearance of ________ from its center to any side wall or partition. 12 Inches 15 Inches 18 Inches 21 Inches None 20. If the static water pressure at the building entrance exceeds ________, an approved pressure-reducing valve (PRV) must be installed. 60 psi 80 psi 100 psi 120 psi None Prove you are human Time is Up!