G18 National Standard Residential Electrician Exam Quiz Welcome to your free G18 National Standard Residential Electrician Exam Quiz REQUIRED - Enter your email address to receive a printable copy of your test results. 1. For a permanently installed residential swimming pool, an outdoor receptacle is required to be located not less than ________ and not more than ________ from the inside wall of the pool. 5 feet ; 10 feet 6 feet ; 20 feet 10 feet ; 25 feet 6 feet ; 15 feet None 2. When installed in a trench in a residential backyard, what is the minimum cover (burial depth) required for a 120-volt UF cable branch circuit that is protected by a 20-ampere GFCI circuit breaker? 6 inches 12 inches 18 inches 24 inches None 3. A ceiling-mounted luminaire (light fixture) that weighs more than ________ must be supported independently of the standard outlet box, unless the outlet box is specifically listed and marked to support the maximum weight. 25 pounds 35 pounds 50 pounds 70 pounds None 4. In a dwelling unit, a hallway requires at least one receptacle outlet if its length is ________ or more. 6 feet 10 feet 12 feet 15 feet None 5. In a dwelling unit, the minimum size of a copper grounding electrode conductor connected solely to a single 8-foot ground rod never needs to be larger than: 8 AWG 6 AWG 4 AWG 2 AWG None 6. Type NM (Nonmetallic-sheathed) cable must be supported and secured at intervals not exceeding: 3 feet 4 feet 4.5 feet 6 feet None 7. In a residential bathroom, a receptacle must be installed within ________ from the outside edge of each sink basin. 12 inches 24 inches 36 inches 48 inches None 8. The maximum number of 12 AWG THHN conductors permitted in a single electrical box with a calculated volume of 21.0 cubic inches is: 8 9 10 12 None 9. In a dwelling unit, a 15- or 20-ampere branch circuit supplying only lighting outlets and receptacles in a bedroom must be protected by: A Ground-Fault Circuit Interrupter (GFCI) An Arc-Fault Circuit Interrupter (AFCI) An Isolated Ground A dedicated grounding-type receptacle None 10. Type NM cable installed in an attic accessible by a pull-down stair must be protected by guard strips if installed across the top of the floor joists within ________ of the attic entrance. 3 feet 5 feet 6 feet 7 feet None 11. When calculating the general lighting load for a dwelling unit, the NEC requires a minimum calculation of ________ per square foot of floor area. 1 volt-ampere 2 volt-amperes 3 volt-amperes 5 volt-amperes None 12. All 125-volt, 15- and 20-ampere receptacles installed in which of the following areas of a dwelling unit require GFCI protection for personnel? Kitchens Laundry areas Crawl spaces - at or below grade level All of the above None 13. The minimum required clear working space depth in front of a residential 120/240-volt electrical panel is: 30 inches 36 inches 42 inches 48 inches None 14. For a single-family dwelling, what is the minimum required rating for the main electrical service disconnecting means? 60 amperes 100 amperes 150 amperes 200 amperes None 15. How many receptacle outlets are mandatory to be installed in a residential kitchen island countertop? At least one receptacle for the first 9 square feet. At least one receptacle per island The NEC no longer mandates receptacles to be installed in kitchen islands. Two receptacles at opposite ends of the island. None 16. What is the minimum required vertical clearance for overhead service-drop conductors (not exceeding 600 volts) passing over a residential driveway? 10 feet 12 feet 15 feet 18 feet None 17. For receptacle outlets installed in a residential living room, the maximum distance measured horizontally along the floor line between any point on the wall and a receptacle shall not exceed: 4 feet 6 feet 8 feet 12 feet None 18. A ground-driven rod electrode must be driven to a depth of not less than ________ into the earth. 6 feet 8 feet 10 feet 12 feet None 19. In a dwelling unit kitchen, what is the minimum number of 20-ampere small-appliance branch circuits required to serve the countertop receptacles? 1 2 3 4 None 20. To qualify as a concrete-encased electrode (often called a "Ufer" ground), a bare copper conductor or conductive reinforcing bar (rebar) must be encased by at least 2 inches of concrete and must have a continuous length of not less than: 10 feet 15 feet 20 feet 25 feet None Prove you are human Time is Up!