KGX Kansas Residential Electrician Quiz Welcome to your KGX Kansas Residential Electrician Quiz 1. In a dwelling unit, which of the following areas is NOT explicitly required by the NEC to have Arc-Fault Circuit Interrupter (AFCI) protection for all 120-volt, 10-, 15-, and 20-ampere branch circuits? Bedrooms Unfinished basements Living rooms Dining rooms None 2. What is the minimum required rating for a branch circuit that strictly supplies the receptacle outlets in a single dwelling unit bathroom? 15 amperes 20 amperes 25 amperes 30 amperes None 3. When installing a surface-mounted incandescent luminaire in a clothes closet, what is the minimum required clearance between the luminaire and the nearest point of a storage space? 6 inches 8 inches 12 inches 18 inches None 4. If a ground rod is used as the sole grounding electrode, what is the maximum required resistance to ground before a supplemental electrode is required? 5 ohms 10 ohms 25 ohms 50 ohms None 5. All 15- and 20-ampere, 125- and 250-volt nonlocking-type receptacles installed in a dwelling unit must have which of the following safety features? Built-in surge protection Isolated ground terminals Tamper-resistant features Weather-resistant ratings (even indoors) None 6. What is the minimum required burial depth for Rigid Metal Conduit (RMC) passing under a residential driveway? 6 inches 12 inches 18 inches 24 inches None 7. For a residential branch circuit rated 120 volts or less, protected by a GFCI rated at 20 amperes or less, what is the minimum cover requirement for direct-buried Type UF cable? 6 inches 12 inches 18 inches 24 inches None 8. In a dwelling unit kitchen, no point along the wall line of a countertop space can be more than how far from a receptacle outlet? 12 inches 24 inches 36 inches 48 inches None 9. For a single-family dwelling, the code requires at least one accessible receptacle outlet at the front and back of the dwelling. What is the maximum permitted height for these required receptacles above grade level? 4 feet 5 1/2 feet 6 1/2 feet 8 feet None 10. A 200-ampere residential service is fed with 2/0 AWG copper ungrounded conductors. What is the minimum required size for the copper grounding electrode conductor (GEC) connected to a driven ground rod? 8 AWG 6 AWG 4 AWG 2 AWG None 11. What is the minimum required rating for the service disconnecting means for a standard one-family dwelling? 60 amperes, 3-wire 100 amperes, 3-wire 150 amperes, 3-wire 200 amperes, 3-wire None 12. When inspecting a rough-in, you notice holes bored through wood framing members for Nonmetallic-Sheathed Cable (Type NM). The edge of the bored hole must be at least how far from the nearest edge of the wood member to avoid needing a steel nail plate? 1/2 inch 3/4 inch 1-1/4 inches 1-1/2 inches None 13. A receptacle is installed near a bathtub. The code dictates a restricted zone where receptacles are not permitted. What are the dimensions of this zone from the top of the bathtub rim? 3 feet horizontally and 8 feet vertically 3 feet horizontally and 6 feet vertically 5 feet horizontally and 8 feet vertically Receptacles shall not be installed within or directly over a bathtub or shower stall. None 14. How many 20-ampere small-appliance branch circuits are required, at a minimum, to serve the receptacle outlets in a dwelling unit kitchen, pantry, dining room, and similar areas? One Two Three Four None 15. At least one receptacle outlet must be installed in a dwelling unit hallway if the hallway, measured continuously along the floor line, is at least how long? 6 feet 8 feet 10 feet 12 feet None 16. When checking the service equipment, you look for the Intersystem Bonding Termination (IBT) used to ground communication systems (like internet and cable). An IBT must have the capacity to connect at least how many intersystem bonding conductors? 2 3 4 5 None 17. Nonmetallic-Sheathed Cable (Type NM) must be secured within what distance of a standard nonmetallic outlet box if the box does not contain integral cable clamps? 6 inches 8 inches 12 inches 18 inches None 18. What is the minimum free length of conductor that must be left at each outlet, junction, and switch point for splices or the connection of luminaires or devices? 4 inches 6 inches 8 inches 12 inches None 19. In a dwelling unit, at least one wall switch-controlled lighting outlet must be installed in every habitable room, bathroom, and: Attic Crawl space Attached garage Utility room None 20. A grounded (neutral) conductor of 6 AWG or smaller must be identified along its entire length by a continuous white or gray outer finish, or by: Green stripes Three continuous white or gray stripes along its entire length on other than green insulation Red tape at the terminations Bare copper wire None Prove you are human Time is Up!