2024 P1 Residential Plumbing Inspector Exam Quiz Welcome to your free 2024 P1 Residential Plumbing Inspector Exam Quiz REQUIRED - Enter your email address and receive a printable copy of your test results. 1. What is the minimum required interior cross-sectional area for a standard residential shower compartment? 600 square inches 800 square inches 900 square inches 1,024 square inches None 2. Every building must have at least one main vent that extends to the outdoors. The vent terminal must extend at least ________ above the roof. 6 inches 12 inches 18 inches 24 inches None 3. If a pipe passes through a framing member and the hole is within ________ of the exposed edge of the member, a steel shield plate must be installed to protect the pipe from screws and nails. 1 inch 1.25 inches 1.5 inches 2 inches None 4. To protect against cross-connection, all outdoor hose bibbs must be equipped with a: Gate valve Check valve Pressure-relief valve Vacuum breaker None 5. If the static water pressure at the building entrance exceeds ________, an approved pressure-reducing valve (PRV) must be installed. 60 psi 80 psi 100 psi 120 psi None 6. Water service pipe shall be installed not less than ________ deep, or not less than 6 inches below the frost line, whichever is greater. 6 inches 12 inches 18 inches 24 inches None 7. For horizontal drainage piping that is 2.5 inches in diameter or smaller, what is the minimum required uniform slope? 1/16 inch per foot 1/8 inch per foot 1/4 inch per foot 1/2 inch per foot None 8. The standpipe serving a clothes washer must extend a minimum of ________ and a maximum of ________ above the trap weir. 12 inches ; 36 inches 18 inches ; 42 inches 24 inches ; 48 inches 18 inches ; 48 inches None 9. What is the minimum required diameter for a residential water service pipe supplying a dwelling? 1/2 inch 3/4 inch 1 inch 1-1/4 inches None 10. The discharge tube from a water heater temperature and pressure (T&P) relief valve must terminate no more than ________ above the floor or waste receptor. 2 inches 6 inches 12 inches 18 inches None 11. A 1.5-inch fixture drain (trap arm) has a maximum allowable distance from the trap weir to the vent fitting of: 4 feet 5 feet 6 feet 8 feet None 12. What is the maximum allowable distance between cleanouts on a horizontal drain line? 50 feet 75 feet 100 feet 125 feet None 13. Slip joints are permitted to be used in residential plumbing systems ONLY on the: Trap outlet, trap seal, or within the trap seal Vents located in concealed spaces Horizontal branch drains inside a wall Water service line underground None 14. When installing horizontal PVC piping for plumbing drainage, what is the maximum allowable distance between supports? 3 feet 4 feet 6 feet 8 feet None 15. If a vent pipe terminates outside, it must be located at least ________ horizontally from any openable window or door, unless it is at least 3 feet above the opening. 3 feet 5 feet 10 feet 12 feet None 16. Standard fixture traps must have a liquid seal depth of not less than ________ and not more than ________. 1 inch ; 3 inches 2 inches ; 4 inches 3 inches ; 6 inches 4 inches ; 8 inches None 17. When an Air Admittance Valve (AAV) is used to vent a fixture, it must be installed a minimum of ________ above the horizontal branch drain or fixture drain being vented. 2 inches 4 inches 6 inches 12 inches None 18. A cleanout must be installed at the base of every: Fixture drain Trap arm Branch interval Drainage stack None 19. If a water heater is installed in a location where a leak could cause structural damage, a galvanized steel or plastic drain pan must be installed. The drain pipe from this pan must have a minimum inner diameter of: 1/2 inch 3/4 inch 1 inch 1-1/4 inches None 20. A water closet must have a minimum clearance of ________ from its center to any side wall or partition. 12 Inches 15 Inches 18 Inches 21 Inches None Prove you are human Please fill in the comment box below. Time is Up!