T17 – Journeyman Electrician Exam Quiz Welcome to your free T17 - Journeyman Electrician Exam Quiz REQUIRED - Enter your email address to receive a printable copy of your test results. 1. When applying the general method of calculation for dwellings, what is the minimum feeder demand on the ungrounded conductors for a one-family dwelling that is to have a cooktop rated 6 kW, three (3) wall-mounted ovens rated at 6, 8, and 3.5 kW, and a broiler rated 3.5 kW? 12.2 kW 18.6 kW 27.3 kW 30.1 kW None 2. If a room air conditioner uses a flexible cord to supply it, the cord may not be more than ______ ft. for a rating of 120-volts, nominal, or ______ ft. for a rating of 208- or 240-volts, nominal. 6, 3 6, 4 8, 10 10, 6 None 3. For a one-family dwelling with a 200 ampere, 120/240-volt, single-phase main service panel, supplied with size 2/0 AWG THW copper ungrounded service-entrance conductors in rigid metal conduit (RMC), what is the minimum allowed size of bonding jumper for the service-entrance conduit? 0/1 AWG copper 2 AWG copper 4 AWG copper 6 AWG copper None 4. With 15-kW or less on portable generators manufactured before __________, listed cord sets or adapters incorporating listed GFCI protection are allowed to be used to meet the GFCI requirement. January 1, 2005 January 1, 2011 January 1, 2014 January 1, 2015 None 5. What is the minimum size THW copper branch-circuit conductor required by the NEC for a 3-phase, continuous-duty, ac motor drawing 70 amperes for phase, when all terminations are rated for 75° C? 3 AWG 4 AWG 5 AWG 6 AWG None 6. When an appliance other than a motor-operated appliance is a continuous load, the branch-circuit rating must be ______ percent of the marked rating or more, or 100 percent of the marked branch-circuit rating or less, and its assembly listed for continuous loading at 100 percent of its rating. 100 125 150 175 None 7. Electrical nonmetallic tubing (ENT) shall be securely fastened in place within __________ of each cabinet, device box, fitting, junction box, or outlet box where it terminates. 12 inches 18 inches 24 inches 36 inches None 8. What is the minimum size for a copper grounding electrode conductor attached to the concrete-encased steel reinforcing bars used as a grounding electrode, when the ungrounded service-entrance conductors for a residence are size 3/0 AWG copper conductors? 2 AWG 4 AWG 6 AWG 8 AWG None 9. The material selected for a grounding electrode conductor should be protected from corrosion or resist any __________ condition extant at the installation. below freezing corrosive high temperature moisture None 10. If the sum of PV system voltages of two monopole subarrays in a bipolar PV system exceeds the rating of the conductors and connected equipment, they must __________ . connected joined separated together None 11. A location used to house four or more persons incapable of self-preservation due to age; mental limitations, mental illness or chemical dependency; or physical limitation due to accident or illness on a(n) __________ basis is a limited care facility. 8 hour or less per day 12 hour 24 hour temporary None 12. Grounding electrode conductor or bonding jumper connections to a grounding electrode must be accessible. A buried or encased connection in a __________, buried, or driven grounding electrode is not required to be accessible. concrete encased electrical metallic tube electrical flexible tube rigid metallic tube None 13. What is the minimum rating for a service disconnecting means when supplied with a 120/240-volt, 3-wire, single phase service for a one-family dwelling? 60 amperes 100 amperes 120 amperes 200 amperes None 14. During lightning events, limiting the length of the primary protector grounding conductors for communications circuits assists in reducing voltage between the buildings communications systems and __________. fire alarm lighting lightning protection power None 15. GFCI protection must be provided in dwelling units, where 125-volt, single-phase receptacle outlets are installed within what distance from the outer edge of a laundry room sink? 5 feet 6 feet 8 feet 10 feet None 16. General-use dimmer switches shall be used only to control permanently installed __________ luminaries (lighting fixtures). compact fluorescent fluorescent halogen incandescent None 17. If communications cables are installed on the surface of ceilings or walls, they must be supported by the building structure so that normal building use will not damage the cable, if it is: concealed exposed hidden both A and B None 18. What is the maximum number of size 14 AWG THHN conductors allowed to be installed in a trade size 3/8 in. flexible metal conduit (FMC) containing bare size 14 AWG grounding conductor, if the FMC has external fittings? 2 3 4 5 None 19. When a branch-circuit conductor supplies more than one motor, it shall have an ampacity of at least ______ of the highest rated motor in the group, and a minimum of 100% of the remaining motor(s) FLC. 25% 80% 100% 125% None 20. What is the minimum allowable trade size intermediate metal conduit (IMC) required to contain a total of ten (10) copper THW conductors in a 20 foot run, five (5) size 1 AWG and five (5) size 3 AWG? 1 1/2 in 2 in 2 1/2 in 3 in None