2021 ICC P1 Residential Plumbing Inspector Exam Quiz Welcome to your free 2021 ICC P1 Residential Plumbing Inspector Exam Quiz REQUIRED - Enter your email address and receive a printable copy of your test results. 1. A Type B or L gas vent must terminate not less than __________ in vertical height above the highest connected appliance draft hood or flue collar. 1 feet 3 feet 5 feet 7 feet None 2. Where plumbing fixtures are installed, the water distribution system and drainage system of any building or premises must be connected to a public sewer system or water supply __________? if available if no private system is available if the owner wants public utilities unless the property already has an approved well and septic system None 3. When water testing a DWV system, each section must be filled with water, and the water has to be held in the section for __________ minutes or more. 10 minutes 15 minutes 20 minutes 25 minutes None 4. The centerline of bidets or water closets must be at least __________ inches from partitions or walls adjacent to it. 12 Inches 15 Inches 18 Inches 24 Inches None 5. Water heaters installed in garages, must be elevated so that the source of ignition is a minimum of how many inches above the garage floor? 6 inches 12 inches 18 inches 24 inches None 6. If a water supply outlet is providing water to a water closet with a flushometer tank, what is the required gpm flow rate, at the point of outlet discharge? 1 gpm 1.6 gpm 2.5 gpm 2.75 gpm None 7. Water service pipe or tubing installed outside of the structure and underground, must have a working pressure rating of at least __________ at 73°F. 40 psi 80 psi 120 psi 160 psi None 8. The drainage fixture unit value (d.f.u.) of a kitchen group with a dishwasher and sink with or without a garbage grinder would be __________? 2 d.f.u 4 d.f.u 6 d.f.u 8 d.f.u None 9. The minimum distance that an open vent terminal from a drainage system is __________ horizontally from any door, openable window or other air intake opening. 2 feet 5 feet 10 feet 12 feet None 10. If a vent terminal extends through a wall it must terminate at least __________ feet above the highest surrounding grade within 10 feet of the vent terminal. 5 feet 10 feet 15 feet 20 feet None 11. What is the minimum expansion tank capacity to be used in a system where a forced hot water system has a system volume of 70 gallons and the system is a pressurized diaphragm type? 6.0 6.5 9.0 10.5 None 12. A single-wall metal pipe connector must have a clearance of at least __________ inches from combustible materials for a residential furnace with a listed draft hood and gas conversion burner. 6 inches 9 inches 12 inches 15 inches None 13. When air testing DWV systems on completion of the rough piping, the portion under test must be maintained at a gauge pressure of 5 pounds per square inch (psi) for a period of __________. 5 minutes 10 minutes 15 minutes 20 minutes None 14. Pipes must be protected from external corrosion by a protective __________, or some other means that will withstand any reaction from the lime and acid of cinder, concrete, or other corrosive material when they must pass through cinder or concrete walls and floors, cold-formed steel framing, or other corrosive material. duct tape metal sleeve plastic or metal sleeve sheathing None 15. If the manufacturer’s instructions on a whirlpool bathtub pump are not specific about minimum size of field fabricated access openings and location, the access opening for the circulation pump must be at least__________? 8 x 8 inches 10 x 10 inches 12 x 12 inches 15 x 15 inches None 16. The minimum sized trap to be used for a shower drainage system is __________? 1.25 inches 1.5 inches 2 inches 2.5 inches None 17. When using a pressure-relief valve to protect a water heater it must be set to open at least ________ psi above the system pressure. 25 psi 50 psi 75 psi 150 psi None 18. One-quarter bends 3 inches in diameter are acceptable for water closet or similar connections, provided that a ___________ flange is installed to receive the closet fixture horn. 2-inch by 3-inch 3-inch by 3-inch 4-inch by 3-inch 5-inch by 3-inch None 19. A horizontal combination waste and vent pipe must have a max. slope of __________. 1/2 unit vertical in 12 units horizontal 1 unit vertical in 12 units horizontal 1 1/2 unit vertical in 12 units horizontal 2 unit vertical in 12 units horizontal None 20. The sump pit must be a minimum of __________ deep. 12 inches 18 inches 24 inches 30 inches None