Sale!

2015 ICC P2 Commercial Plumbing Inspector Exam Prep Course!

Learn how to become an ICC P2 Commercial Plumbing Inspector. (Online and self-paced)

Complete our online 2015 P2 Commercial Plumbing Inspector exam preparation course, then pass the ICC P2 exam online via ICC PRONTO.

$169.00

* Shipping fees apply for the options not fully online.

Category:

Master the Code, Study To Pass Your 2015 ICC P2 Commercial Plumbing Inspector Exam.

With our help, Passing the ICC P2 Commercial Plumbing Inspector test has never been easier! We guarantee it! | (2018 Course also available)

Your Blueprint For Success. You Can Pass the ICC P2 Exam. We Guarantee it!

Refresh your 2015 IPC, 2015 IFGC, and A117.1-2009 code knowledge, successfully pass your 2015 ICC P2 Plumbing Inspector Exam. Our comprehensive interactive Plumbing Inspector exam preparation system is your best, most affordable path to guarantee ICC certification!

Get your ICC P2 Commercial Plumbing Inspector Certification. We provide you with the study materials required to PASS THE ICC P2 EXAMOur 100% money-back guarantee backs this course.


How To Use Our Online Exam Center

Study our “Navigating the 2015 IPCA Code Primer – For ICC P2 Commercial Plumbing Inspectors”. This eManual will familiarize you with the code’s structure within the 15 chapters of the 2015 IPC.

STUDY our “Navigating the 2015 IFGCA Code Primer – This eManual will familiarize you with the use, layout, and content of chapters 1 through 8 of the 2015 IFGC.

PRACTICE utilizing our “Online Exam Center” (Provides over 1300 practice questionsallows you to study specific questions and answers as well as take multiple practice exams.

The course includes

  • eManual (Navigating the 2015 IPC. A Code Primer – For the ICC P2 Commercial Plumbing Inspector exam)
  • eManual (Navigating the 2015 IFGC. A Code Primer – For the ICC P2 Commercial Plumbing Inspector exam)
  • Insert (Navigating the A117.1-2009 – For the ICC P2 Commercial Plumbing Inspector exam)
  • Printable Worksheets (Companion to eManuals)
  • Online Exam Center (Practice looking up answers in your codebook, Take full-length simulated exams).

eManual: NAVIGATING THE 2015 IPC “A Code Primer – For The ICC P2 Commercial Plumbing Inspector Exam”.

Our “NAVIGATING THE IPC” manual helps students review the (IPC) International Plumbing Code. The manual focuses specifically on the relationship of the IPC to the P2 Certification Exam. When you master the code, you master the exam!

This manual is the starting point for the TLC Certification Training Program. Designed specifically for the P2 Commercial Plumbing Inspector exam, this manual will familiarize you with the use, layout, and content of chapters 1 through 15 of the 2015 IPC.  The manual also provides a comprehensive review of study questions similar to those found on the ICC P2 Exam.

Textbook includes

  • The purpose and layout of the code
  • How to navigate the IPC
  • Code reference exercises, speed drills
  • Exam Breakdown
  • Using the Table of Contents
  • Breaking down questions by subject (Chapters 1-15)
    • Keyword Identification, how to Identify the subject of a question for easy reference.
    • How to search for a code article by referencing the INDEX
    • Code reference example questions with in-depth solutions.

ICC allows the use of your 2015 IPC codebook when taking the P2 exam!


eManual: NAVIGATING THE 2015 IFGC “A Code Primer – For The ICC P2 Commercial Plumbing Inspector Exam”.

Our “NAVIGATING THE IFGC” manual helps students review the (IFGC) International Plumbing Code. The manual focuses specifically on the relationship of the IFGC to the P2 Certification Exam. Designed specifically for the P2 Commercial Plumbing Inspector exam, this manual will familiarize you with the use, layout, and content of chapters 1 through 8 of the 2015 IFGC.  The manual also provides a comprehensive review of study questions similar to those found on the ICC P2 Exam.

Textbook includes

  • The purpose and layout of the code
  • How to navigate the IFGC
  • Code reference exercises, speed drills
  • Exam breakdown
  • Using the Table of Contents
  • Breaking down questions by subject (Chapters 1-8)
    • Keyword Identification, how to Identify the subject of a problem for easy reference.
    • How to search for a code article by referencing the INDEX
    • Code reference example questions with in-depth solutions.

ICC allows the use of your 2015 IFGC codebook when taking the P2 exam!


INSERT  NAVIGATING THE A117.1-2009 Chapter 6 – For ICC P2 Commercial Plumbing Inspector Exam:

Our “NAVIGATING THE A117-1-20009” Insert helps students review chapter 6 of the (A117.1-2009) Accessible and Usable Buildings and Facilities. The Insert focuses specifically on the relationship of chapter six of the A117.1-2009 to the P2 Certification Exam. Designed specifically for the P2 Commercial Plumbing Inspector exam, this insert also reviews study questions similar to those found on the ICC P2 Exam.

Insert includes

  • Intro to the ICC A117.1-2009
  • How to navigate the A117.1-2009
  • Exam breakdown
  • Using the Table of Contents
  • Breaking down questions by subject (Chapter 6)
    • Keyword Identification, how to Identify the subject of a problem for easy reference.
    • How to search for a code article by referencing the INDEX
    • Code reference example question with an in-depth solution.

ICC allows the use of your ICC A117.1-2009 codebook when taking the P2 exam!


Online Exam Center – STUDY QUESTIONS & PRACTICE EXAMS

Access eManuals, Study Questions, and Simulated Exams From Any Device With Internet Access!

Our online practice questions provide you with a framework to practice utilizing chapters 1-15 of your 2015 IPC and chapters 1-8 of your 2015 IFGC codebook. This process of constantly utilizing your codebook to answer test questions builds up your speed and code knowledge. Our course provides you with the required skill set to pass your P2 Plumbing inspector exam easily.

Four modes of study!

  • Chapter Study Mode: Covers over 1300 ICC P2 exam practice questions & answers. (Organized as Question – Answer – Code Location)
  • Flashcard Mode: Online Virtual Flashcards provide randomized access to our entire question set and are an ideal setting to practice answering exam questions. (Organized as Question – Answer – Code Location)
  • Chapter Tests: Provide real-time feedback on each chapter of our study materials, enabling you to concentrate on chapters that need improvement.
  • Simulated Final Exams: Simulates the taking of your ICC P2 Plumbing inspector exam.
    • Full length (Exact  number of questions as on P2 Exam)
    • Timed (Exact amount of time as actual ICC P2 exam)
    • Randomized (Questions are randomized, all exams are unique)
    • Properly Balanced (Balanced according to the ICC Exam schedule guaranteeing a realistic P2 exam simulation)

Take as many simulated final exams as you want! (These exams help you to gain the knowledge, speed, and confidence needed to pass your ICC P2 exam effortlessly)


One-year online access: Full access membership to our online study center. Experience the convenience of learning at home or in the office, saving valuable travel time to an in-person course.


THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF, 2015 (IPC) INTERNATIONAL PLUMBING CODE, AS WELL AS THE 2015 (IFGC) INTERNATIONAL FUEL GAS CODE. IF YOU DO NOT POSSESS COPIES OF THESE CODEBOOKS, PURCHASE THEM IMMEDIATELY.

Learn what’s in the ICC 2015 P2 Exam!

Knowing what to expect is half the battle; proper preparation takes care of the rest. Our ICC P2 code foundation education helps you master the 2015 IPC, A117.1-2009, and 2015 IFGC, ensuring you are in the best possible position for success.

How many questions are there in the actual 2015 ICC P2 Exam?

Answer: There are 60 code questions sourced from the 2015 IPC, 2015 IFGC, and ICC A117.1-2009.


How much time are you allowed to complete the P2 exam?

Answer: You have no more than two hours and thirty minutes (Average, less than two minutes per question) to complete the P2 exam.


What am I allowed as reference materials when taking my P2 Exam?

Answer: You are allowed the 2015 IPC, 2015 IFGC, and ICC A117.1-2009. Exam questions come from these codebooks.


What percentage of questions do I need to get right to pass the P2 exam?

Answer: You must get 45 or more questions correct  (75%) to pass the P2 exam.


What type of questions will I be asked on my 2015 P2 exam?

Answer: The ICC P2 exam is a multiple-choice exam. Each question has four potential answers, with one answer being the most accurate or correct solution to the question. Specific question makeup is as follows:

  • General Requirements (8%)
    • Piping Protections 5%
    • Piping Installation, Support, Sleeving, and Penetrations 3%
  • Fixtures (15%)
    • Fixture and Material Approvals 2%
    • Installation, Location, Clearance, and Access 5%
    • Flow Rates 3%
    • Accessibility 5%
  • Water Heaters (12%)
    • Installation Requirements 5%
    • Gas Piping, Combustion Air, and Venting 7%
  • Water Supply and Distribution (18%)
    • Materials, Joints, and Connections 3%
    • Identification, Sizing, and Valving 5%
    • Protection Against Contamination and Treatment 5%
    • Nonpotable Water Distribution Systems 5%
  • Sanitary Drainage (13%)
    • Materials and Fittings 3%
    • Sizing of System 4%
    • Valves, Sumps, Ejectors, and Cleanouts 3%
    • Indirect Waste 3%
  • Vents (15%)
    • Materials, Joints and Connections, and Grade 5%
    • Sizing, Method, and Installation 10%
  • Traps, Interceptors, Separators, Special Piping, and Storage Systems (9%)
    • Installation Requirements 5%
    • Chemical Treatment, High Temperature, & Neutralization Systems 4%
  • Storm Drainage (5%)
    • Materials Sizing and Installation 3%
    • Sub-soil Sub-drains 2%
  • Health Care Plumbing (5%)
    • Materials and Installation 2%
    • Service and Distribution Piping 3%

Next, take your ICC P2 exam at home, ONLINE 24/7!

Take your exam at home via PRONTO (Proctored Remote Online Testing) or take your exam at any Pearson|VUE test center

TAKE YOUR ICC P2 EXAM ONLINE WITH ICC PRONTO or TAKE YOUR TEST AT THE CLOSEST PEARSON|VUE TEST CENTER

ICC PRONTO provides an at-home option for taking your ICC exams 24/7.
CLICK HERE – For more information or to log into the ICC – PRONTO portal.

ICC Inspector exams are also available in person at Pearson|Vue testing centers across the country.
CLICK HERE – For more information or to set up an exam with Pearson|Vue. 

Pricing for each exam is the same regardless if you choose Pearson|Vue or ICC PRONTO to administer your final exam.


PRONTO REQUIREMENTS/RECOMMENDATIONS FOR TAKING THE P2 EXAM

TEST-TAKING – Room: Where you take your final ICC exam.

  • Requirement: Only one person is allowed in the room; if someone else enters while you are testing, the Proctor will automatically eject you from the exam.
  • Recommendations: The room should be in a quiet place with a door that can remain shut. Again, make sure you are alone, comfortable, and fully prepared to stay in full view of the webcam for the duration of your exam.

Bathroom Breaks: You may take up to a 5-minute bathroom break at any time during the exam.

  • Requirement: If a break exceeds the 5-minute mark, the Proctor will terminate the exam. The time clock continues to count down during any breaks. Additionally, a new desk scan is required before you are allowed to continue taking the exam.
  • Recommendations: Bathroom breaks waste your time. Be sure to take care of your business before your exam begins.

YOUR COMPUTER: You may use any PC or Laptop if it has a webcam, speakers, and a microphone

  • Requirement: Your computer must be connected to the internet. If using a laptop, use it as a stand-alone computer. Do not plug it into a docking station with monitors attached.

Required Operating System:

  • Windows XP – Windows 10
  • Mac OS X 10.8 (Mountain Lion) – 10.13 (High Sierra)

Internet Connection: You must have a stable internet connection

  • Requirement: minimum speed of 2MB, upload, and download.
  • Recommendations: While you can use WiFi, we highly recommend using wired high-speed internet access as WiFi may not be stable.

Browser (with pop-up blocker disabled):

  • Google Chrome
  • Mozilla Firefox

ProctorU Technical Support

  • Call: 1-855-772-8678, Option 1
  • Before connection time, you can submit a support ticket
  • During connection time, live chat support will be available.

Printed Manuals: P2 Exam
Offline Course Support Aid (Sold Separately) $60.00

Provides printed versions of the Navigating the 2015 IPC and Navigating the 2015 IFGC eManuals. Read-only versions of these manuals are provided online in the P2 Commercial Plumbing Inspector exam course.


Order only if you require a printed manual for offline study. Our P2 course provides online access to these manuals.

Add the 2015 IPC Softcover
Required Codebook (Sold Separately) $91.75

The (IPC®) International Plumbing Code® provides minimum regulations for plumbing facilities in terms of both performance & prescriptive objectives and provides for the acceptance of new and innovative products, materials, and systems.

2015 IPC SOFTCOVER

$91.75

* Shipping fees apply for the options not fully online.

Category:

The 2015 IPC is a REQUIRED CODEBOOK for anyone taking the 2015 P2 Commercial Plumbing Inspectors exam.

Provides minimum regulations for plumbing facilities regarding both performance and prescriptive objectives and provides for the acceptance of new innovative products, materials, and systems. The IPC® also includes its companion document, 2015 International Private Sewage Disposal Code® that contains provisions for design, installation, and inspection of private sewage disposal systems and provides flexibility in developing safe, sanitary systems.

The 2015 IPC® contains many significant changes, including:

  • Public toilet facilities are not required for occupancies that have limited areas for public access.
  • Water temperature limiting devices are required for footbaths and head shampoo sinks.
  • In a replacement water heater installation situation, when a nearby drain point is unavailable for the required pan, a code modification allows the pan to be used without a drain line.
  • Fixtures such as water closets and urinals that utilize nonpotable water must be identified with words and a symbol that nonpotable water is being used. The color purple is established for identifying distribution piping conveying nonpotable water.
  • The application of a primer to drain, waste, and vent PVC pipe and fittings before solvent cementing is not required for 4-inch pipe size and smaller.

 

ISBN-10: 160983481X
ISBN-13: 978-1609834814

2015 IPC Fast-Tabs
Codebook Navigation Aid (Sold Separately) $13.45

Tab your Codebook. Fast-Tabs help you navigate the 2015 IPC quickly and efficiently. Fast-tabs are a must-have item for IPC users and can dramatically lower the time spent searching through the codebook.


You are allowed to use IPC Fast-Tabs when taking your P2 Exam!

2015 IPC Quick-Card
Code Reference Aid (Sold Separately) $7.95

This six-page laminated card places 2015 IPC essentials at your fingertips and helps familiarize you with key code sections. Quick-Cards are a useful addition to your professional code library.


You can use IPC Quick-Cards if in a 3-ring binder when taking your P2 Exam.

Add the 2015 IFGC Softcover
Required Codebook (Sold Separately) $91.75

The scope of the (IFGC®) International Fuel Gas Code® addresses the design and installation of fuel gas systems and gas-fired appliances through requirements that emphasize performance.

2015 IFGC SOFTCOVER

$91.75

* Shipping fees apply for the options not fully online.

Category:

The 2015 IFGC is a Required Codebook for 2015 P2, Commercial Plumbing Inspector Exam.

The IFGC contains regulations to safeguard life and property from fires and explosion hazards. Topics include general precautions, emergency planning, and preparedness, fire department access and water supplies, automatic sprinkler systems, fire alarm systems, special hazards, and the storage and use of hazardous materials.

The 2015 IFGC® contains many important changes, including

  • The section on the protection of piping has been completely rewritten.
  • Line regulators installed in rigid piping must have a union installed to allow removal of the regulator.
  • Specific installation requirements were added for the safe installation of ANSI Z21.69 connectors for commercial cooking appliances.
  • The new text recognizes the use of dryer exhaust duct power ventilators (DEDPV) for installations that exceed the allowable exhaust duct length for clothes dryers.

 

ISBN 10: 1609834771
ISBN 13: 9781609834777

2015 IFGC Turbo-Tabs
Codebook Navigation Aid (Sold Separately) $17.50

Tab your Codebook. Fast-Tabs help you navigate the 2015 IFGC quickly and efficiently. Fast-tabs are a must-have item for IFGC users and can dramatically lower the time spent searching through the codebook.


You are allowed to use IFGC Fast-Tabs when taking your P2 Exam!

Add the ICC A117.1-2009
Required Codebook (Sold Separately) $47.50

The scope of the A117.1-2009®) Accessible and Usable Buildings and Facilities® Addresses making sites, facilities, buildings, and elements accessible to and usable by people with such physical disabilities as the inability to walk, reliance on walking aids, visual and hearing impairments, reaching and manipulation disabilities, lack of stamina, and extremes of physical size.

ICC A117.1-2009 SOFTCOVER 

$47.50

* Shipping fees apply for the options not fully online.

Category:

The A117.1-2009 is a Required Codebook for the ICC P2 Commercial Plumbing Inspector Exam.

The specifications in this standard make sites, facilities, buildings, and elements accessible to and usable by people with such physical disabilities as the inability to walk, difficulty walking, reliance on walking aids, blindness, and visual impairment, deafness and hearing impairment, incoordination, reaching and manipulation disabilities, lack of stamina, difficulty interpreting and reacting to sensory information, and extremes of physical size. This standard intends to allow a person with a physical disability to independently get to, enter, and use a site, facility, building, or element. Includes:

  • Coordination of requirements for the various types of dwelling units
  • Technical requirements for Type C (Visitable) Units added.
  • Variable Message Signs (i.e., gate information in train stations and airports)
  • Better consistency of sign requirements regarding when raised characters and Braille are required
  • Location of toilet paper dispenser (more design options, recessed fixtures addressed, single point of measurement, etc.)
  • New chapter for a variety of types of recreational facilities

These newly revised criteria are intended to provide a level of coordination between the accessible provisions of this standard and the revised Americans with Disabilities Act (ADA/ABA AG).

This is a must-have reference for facility professionals, building owners, architects, designers, and code officials that want to stay up to date with the requirements of this Accessibility Standard.

 

ISBN-10: 1580019188
ISBN-13: 978-1580019187

Take our FREE P2 Commercial Plumbing Inspector practice Test.

Pass this 20 question free ICC 2015 P2 practice test to glimpse where you stand! These free ICC P2 practice test questions are similar to the problems you will encounter when taking your actual ICC P2 Certification exam.

  • If you answer sixteen or more of these free ICC practice questions correctly, you are in pretty good shape.
  • However, if you miss five or more questions, get this course, you are in danger of failing your ICC test.

An existing plumbing system that is __________ must be brought into compliance with the International Plumbing Code (IPC).

Correct! Wrong!

What is the term for a valve made to permit air to enter a plumbing drainage system one-way, when the pressure in the piping system becomes negative? The valve must seal the vent terminal at zero pressure by gravity and when the internal pressure is positive. The purpose of such a valve is to let air go into a system so that there is no need for a vent to extend to open air, and to keep sewer gases out of a building.

Correct! Wrong!

If the waste line is __________ , a domestic dishwashing machine waste line is allowed to discharge into a wye-branch fitting on the tailpiece of a kitchen sink.

Correct! Wrong!

Inspection for underground piping must be made before any ____________ is put in place, but after ditches or trenches are excavated and bedded, and piping is installed.

Correct! Wrong!

If a hot water storage tank or storage tank-type water heater is installed where leakage from the tank will cause damage, it must be installed in a galvanized steel pan made of metal at least ___________ gauge (0.0236 inch or 0.6010 mm) thickness, or other such pans that are approved for this purpose.

Correct! Wrong!

A clearance of __________ inches or more is required in front of an appliance, when outdoor combustion air is provided through a single opening.

Correct! Wrong!

If the manufacturer’s instructions allow the usage, what is the maximum distance in developed length allowed from fixture outlet to the inlet of a grease interceptor serving as a trap?

Correct! Wrong!

Where gravity flow cannot be used to discharge building sub drains to the sewer, then a tightly covered and vented ____________ with automatic pumping equipment or other approved methods to lift liquid and discharge it into the building gravity drainage system will be used. Unless it is in an existing structure, this system may not receive any drainage that is able to be discharged into the building sewer by gravity.

Correct! Wrong!

Piping supports for plumbing must be designed and installed in accordance with the ___________ seismic force provisions where earthquake loads are applicable in relation to building codes.

Correct! Wrong!

If the code requirements and the installation instructions from the manufacturer conflict, then the requirements that are __________ are applicable.

Correct! Wrong!

If a storage water heater operates ___________, it must have an approved self-closing (levered) pressure relief valve and temperature relief valve or combination valve that conforms to ANSI Z21.22-2006. The relief valve may not be used to control thermal expansion.

Correct! Wrong!

Permanent openings for natural ventilation in a garage where hydrogen-generating appliances are locate must have a free area of at least __________ square foot per 1,000 cubic feet of volume in the garage.

Correct! Wrong!

How much projected roof area is a 4-inch horizontal pipe with a 2-percent slope able to drain in a 3-inch rainfall area?

Correct! Wrong!

What is the proper name for a distance of 8 feet (2438 mm) or more in vertical developed length between connections of a drainage stack to horizontal branches? The measurement begins at the highest horizontal branch connection, and then down the stack.

Correct! Wrong!

Return air for a forced air furnace should not generally be taken from a __________.

Correct! Wrong!

The Chapter 13 provisions cover the design, materials, construction, and installation of __________ systems for collection, storage, treatment, and distribution, in accordance with the local jurisdiction’s laws, rules, and ordinances.

Correct! Wrong!

Except in engineered systems, a single wall chimney connector must have a horizontal length of no more than __________ the height of the vent or chimney.

Correct! Wrong!

What kind of fittings must be recessed drainage type?

Correct! Wrong!

Hangers for 3/4-inch nominal diameter carbon steel pipe being sued to supply natural gas to an appliance must not be more than ____________ feet apart.

Correct! Wrong!

Subsoil drains must be at least __________ in diameter. If a building is subject to backwater, then the subsoil drain must be protected by a backwater valve that is accessibly located. Subsoil drains may discharge to a drain, dry well, sump, trapped area, or above-ground approved location.

Correct! Wrong!