2024 ICC M1 Residential Mechanical Inspector Exam Quiz Welcome to your free 2024 ICC M1 Residential Mechanical Inspector Exam Quiz REQUIRED - Enter your email address and receive a printable copy of your test results. 1. In vented floor furnaces, the furnace register must be located a min. of __________ below any projecting combustible materials. 1 foot 3 feet 5 feet 7 feet None 2. Piping for a secondary drain or auxiliary drain pan required for a cooling or evaporator coil, must maintain a min. horizontal slope in the direction of discharge a min. of __________. 1/8 unit vertical in 12 units horizontal 1/4 unit vertical in 12 units horizontal 1/3 unit vertical in 12 units horizontal 1/2 unit vertical in 12 units horizontal None 3. Clothes dryer exhaust ducts must not be joined with screws that protrude more than __________ into the inside of the duct. 1/8 inch 1/4 inch 1/3 inch 1/2 inch None 4. Metal ducts in underground duct systems must be protected from corrosion in an approved manner or must be completely encased in concrete a min. of __________ thick. 1 inch 2 inch 3 inch 4 inch None 5. Return air openings for heating, ventilation and air conditioning systems must be located a min. of __________ from an open combustion chamber or draft hood of another appliance in the same room or space. 5 feet 10 feet 15 feet 20 feet None 6. The horizontal run of an uninsulated connector to a natural draft chimney must not exceed what percentage of the height of the vertical portion of the chimney above the connector? 25% 50% 75% 100% None 7. Unless otherwise specified, gas piping systems installed underground must be at least __________ inches below grade. 6 inches 12 inches 18 inches 24 inches None 8. In garages, appliances that have an ignition source must be elevated such that the source of ignition is not less than __________ above the floor. 12 inches 18 inches 24 inches 30 inches None 9. Exhaust systems capable of exhausting more than __________ must be mechanically or passively provided with makeup air at a rate approximately equal to the exhaust air rate. 200 cubic feet per minute 300 cubic feet per minute 400 cubic feet per minute 500 cubic feet per minute None 10. Condensate piping from cooling coils and evaporators must maintain a minimum horizontal slope __________ in the direction of discharge. 1/8 unit vertical in 12 units horizontal 1/4 unit vertical in 12 units horizontal 1/2 unit vertical in 12 units horizontal 3/4 unit vertical in 12 units horizontal None 11. Clothes dryer exhaust ducts must be supported at maximum intervals of __________. 6 feet 4 feet 18 feet 24 feet None 12. Gas-fired appliances must be provided with combustion air that complies with __________. IRC - Chapter 24 manufacturer's installation instructions NFPA 31 NSFA 35 None 13. Natural draft gas vents serving wall furnaces must terminate at a minimum elevation of __________ above the bottom of the furnace. 6 feet 12 feet 18 feet 24 feet None 14. Hydronic piping systems must be tested hydrostatically at a pressure of 1-1/2 times the maximum system design pressure, but not less than 100 psi for a minimum duration of __________. 10 minutes 15 minutes 20 minutes 25 minutes None 15. Supply piping used in the installation of oil burners and appliances must be a min. of __________ pipe. 1/8-inch 1/2-inch 3/8-inch 1-inch None 16. What is the max input rating of an unvented room heater? 20,000 Btu/h 40,000 Btu/h 60,000 Btu/h 80,000 Btu/h None 17. A ground source heat pump loop system shall be pressure tested with water for __________ minutes with no observed leaks prior to the backfilling of the connection trenches. 5 Minutes 10 Minutes 15 Minutes 30 Minutes None 18. The cross sectional area of a chimney flue connected to a solid-fuel-burning appliance shall be a maximum of _______________ times the area of the flue collar, unless specified otherwise in the manufacturer’s installation instructions. 1 1/2 2 3 4 None 19. If a fuel-gas appliance requires a minimum clearance without protection 1 of 36 inches above the appliance to combustible material, and has a 1/2 -inch thick insulation board over 1-inch glass fiber batts as protection, the minimum clearance may be reduced to _______________. 9 inches 24 inches 12 inches 18 inches None 20. Return air can be taken from a kitchen, so long as the air openings are located a min. of _____ from the cooking appliances and only serve the kitchen. 6 feet 8 feet 10 feet 12 feet None