Sale!

— 2015 ICC B1 Residential Building Inspector Certification Course!

Passing your ICC B1 Exam has never been easier!

Complete our self-paced 2015 B1 Residential Building Inspector Exam Preparation Course then take the actual ICC exam online via ICC PRONTO.

Rapidly become 2015 ICC B1 certified without leaving the comfort of your home or office.

Many home inspectors also use ICC B1 Residential Building inspector Certification as a crucial part of their Inspector Certification portfolio.

$199.00 $169.00

Add to cart
Category:

Pass the ICC B1 Residential Building Inspector exam!

We provide everything you require to achieve ICC B1 Residential Building Inspector status. PASS YOUR 2015 ICC B1 EXAM. You will pass, we guarantee it. Order our ICC B1 Course today and save $30

With our help, Preparing for your ICC B1 Residential Building Inspector Test has never been easier! You will pass the 2015 B1 exam, we guarantee it! (2018 Course also available)

YOUR ROADMAP TO SUCCESS. PASS THE ICC B1 EXAM, GUARANTEED!

Refresh your 2015 IRC code knowledge, successfully pass your 2015 ICC B1 Residential Building Inspector Exam. Our comprehensive interactive Residential Building Inspector exam preparation program is your best, most affordable path to guarantee ICC certification!

Get your 2015 ICC B1 Residential Building Inspector Certification. We provide you with everything required to PASS THE ICC B1 EXAM. Our 100% money-back guarantee backs this course.

STUDY our “Navigating the 2015 IRC: A Code Primer – For ICC B1 Residential Building Inspectors”. This manual familiarizes you with the structure and function of the code contained within the first 11 chapters of the 2015 IRC. ICC International Residential Code for One and Two-Family Dwellings.

PRACTICE utilizing our “Online Study Center,” providing over 600 practice questions. Study-specific questions and answers and take timed simulated practice exams.

The course includes

  • Textbook (Navigating the 2015 IRC. A Code Primer – For the ICC B1 Residential Building Inspector exam)
  • FastTabs (Tab your codebook)
  • QuickCard. (Quick code lookup laminated cheat sheets)
  • Online Study Center (Practice looking up answers in your codebook, Take full length simulated exams).


TEXTBOOK – NAVIGATING THE 2015 IRC – A Code Primer – For the ICC B1 Residential Building Inspector Exam

Our “NAVIGATING THE 2015 IRC” manual helps students review the (IRC) International Residential Code. This manual focuses specifically on the relationship of the IRC to the B1 Certification Exam. When you master the code, you master the Exam!

This manual is designed specifically for the B1 Residential Building Inspector Exam. The manual familiarizes you with the use, layout, and content of the first 11 chapters of the 2015 IRC. The manual also provides a comprehensive review of study questions similar to those found on the ICC B1 Exam.

Textbook includes

  • The purpose and layout of the code
  • How to navigate the IRC
  • Code reference exercises, speed drills
  • Exam Breakdown
  • Using the Table of Contents
  • Breaking down questions by subject (Chapters 1-11)
    • Keyword Identification, how to Identify the subject of a question for easy reference.
    • How to search for a code article by referencing the INDEX
    • Code reference example questions with in-depth solutions.

This manual covers the use, layout, and content of the first 11 chapters of the IRC. This manual is the starting point for the TLC ICC Certification Training Program.

You are allowed by ICC to use the 2015 IRC codebook when taking your B1 Exam!


FAST-TABS –  Quick reference tabs for your 2015 IRC codebook, approved for use when taking your ICC exam:

Tab your Codebook. Fast-Tabs help you navigate the 2015 IRC quickly and efficiently. Fast-tabs are a must-have item for IRC users and can dramatically lower the time spent searching through the codebook.

You are allowed by ICC to use our codebook tabs when taking your B1 Exam!


QUICK-CARD – Quick lookup reference of key IRC codes:

This 6-page laminated card places IRC essentials at your fingertips and helps familiarize you with key code sections. Quick-Card compiles Building, Mechanical, Plumbing, Fuel Gas, and Electrical requirements for the 2015 International Residential code into one easy reference. Quick-cards are a useful addition to your professional code library.

Requirements include:

Footings ● Floor Framing ● Wall Framing ● Masonry Walls ● Roof Framing ● Interior Dimensions ● Means of Egress ● Smoke Alarms ● HVAC ● Plumbing ● Electrical.


ONLINE STUDY CENTER:

Chapter Study Mode – Flash Card Study Mode – Chapter Test Mode – Final Exam Simulation Mode

Access practice questions & simulated exams from any device with internet access! Online features include virtual flashcards, 600+ practice questions, chapter exams, & mock final exams.

Our “Online Study Center” allows you to focus your study time by reviewing only the unfamiliar questions. Mark questions you know as DONE, and they will appear only on the mock final exams. Practice exams also provide additional feedback on questions answered incorrectly.

Online exercises appear as

  • Chapter Study Mode (Study by Chapter) 
  • Flash Card Mode (Study by random questions/answers)
  • Chapter Test Mode (Chapter tests lead to a greater understanding of the layout of the code)
  • Final Exam Simulation Mode. (Final exams consist of full-length, timed practice tests similar to the ICC exam).

SIMULATED ONLINE EXAMS: Chapter tests and final exams allow you to check your progress while you master our study material. Practice tests provide real-time feedback and enable you to concentrate only on subjects needing improvement. Practice exams help you rapidly gain confidence and knowledge to pass your ICC Certification Exam effortlessly.

ONE YEAR ONLINE ACCESS: 1-year full access membership to our Online Study Center. Conveniently study in your home or office without wasting valuable time traveling to distant ICC classes. Our program is a reliable and affordable way to pass your 2015 B1 Residential Building Inspector Exam at home, online.


THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2015 (IRC). IF YOU DO NOT OWN A COPY OF THE CODEBOOK, YOU SHOULD ACQUIRE ONE IMMEDIATELY.

Now take your ICC B1 exam at home, ONLINE 24/7!

Take your exam at home via PRONTO (Proctored Remote Online Training)
Print your building inspector certificate immediately upon passing the exam.

ICC PRONTO provides an additional at-home option for taking your ICC B1 exam. Now you have the option of going to your closest Person | Vue testing center OR choosing to take the exam from your home or office via ICC PRONTO.

ICC Inspector exams are available at Pearson | Vue testing centers across the country. Pricing for each exam is the same regardless if you choose Pearson | Vue or ICC PRONTO to administer your final exam.

  • For more information or to log into the ICC – PRONTO portal. CLICK HERE
  • For more information or to set up an exam with Pearson | Vue. CLICK HERE

B1 EXAM BREAKDOWN:

60 QUESTIONS – 2 HOUR TIME LIMIT – OPEN BOOK EXAM – 75%+ TO PASS

Code Administration: 4%

  • Project Administration – 2%
  • Public Information and Legal – 2%

Building Planning: 8%

  • Unit Separation – 3%
  • Building Location – 3%
  • Room and Opening Dimensions – 2%

Footings and Foundations: 16%

  • Footings – 5%
  • Stepped Footings and Special Foundation – 3%
  • Columns and Piers – 3%
  • Site Preparations, Foundation, and Basement Walls – 5%

Floor Construction 14%

  • Lumber Quality – Floors – 3%
  • Floor Joist Framing – 3%
  • Concrete Slab Inspection – 2%
  • Subflooring and Decking – 2%
  • Crawl Spaces – 2%
  • Draft stops – 2%

Wall Construction and Coverings 27%

  • Lumber Quality; Walls – 4%
  • Wood Framing; Walls – 4%
  • Header Spans – 2%
  • Steel Framing – 2%
  • Fireblocking – 2%
  • Masonry Materials and Placement – 2%
  • Concrete Wall Inspection – 2%
  • Braced Wall Panels – 2%
  • Interior Coverings – 2%
  • Exterior Sheathing, Veneers, and Weather-Resistant Coverings – 3%
  • Exterior Plaster, Stucco, and Lath – 2%

Roof/Ceiling Construction 14%

  • Roof/Ceiling Insulation and Vapor Barriers – 2%
  • Attics/Ceiling – 2%
  • Roof Framing – 4%
  • Roof Sheathing – 2%
  • Roofs and Roof Coverings and Re-roofing – 2%
  • Fireplaces and Chimneys – 2%

Public Safety and Special Construction 17%

  • Means of Egress – 4%
  • Exit Stairways and Ramps – 3%
  • Exterior Construction – 3%
  • Smoke Detectors – 2%
  • Flamespread of Insulation and Finishes – 2%

RESPONSIBILITIES: At this level of certification the duties of a B1 Certified Residential Inspector include the following.

  • Inspecting one-and-two-family dwellings and town-homes, of no more than three stories in height.
  • Inspecting accessory structures.
  • Determine the compliance with the Building Codes and Standards adopted by their jurisdiction.

2015 IRC for One and Two-Family Dwellings.
Required Codebook

If you don’t own a copy of the 2015 IRC, (International Residential Code) that’s OK. We have you covered. Add the codebook and you are good to go.


THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2014 (IRC). IF YOU DO NOT OWN A COPY OF THIS CODE-BOOK, ACQUIRE ONE IMMEDIATELY.

 

2015 IRC SOFTCOVER 

You must have a copy of the 2015 IRC to use this program!

Pass the ICC B1, M1, P1, and E1 Exam. The ICC Inspector Certification exam is an open book test.

You must possess a copy of the 2105 IRC when taking your ICC B1, M1, P1, and E1 Residential Inspector Exams.

$144.00

Add to cart
Category:

The 2015 IRC is a REQUIRED CODEBOOK for 2015, B1, M1, P1, and E1 Residential Building Inspector Exams.

This comprehensive code compiles all building, plumbing, mechanical, fuel gas and electrical requirements for non-commercial one- and two-family dwellings in one convenient code. The regulations cover dwellings and townhouses up to three stories.

The 2015 IRC® contains many important changes including:

  • Common walls separating townhouses must now be rated for 2 hours when an automatic fire sprinkler system is not installed.
  • Remodeling of an existing basement does not trigger the emergency escape and rescue opening requirements unless a new bedroom is created.
  • Ramps that do not serve the required egress door are now permitted to have a slope not greater than 1 unit vertical in 8 units horizontal.
  • Carbon monoxide alarms now require connection to the house wiring system with battery backup. A carbon monoxide alarm is required in bedrooms when there is a fuel-
  • fired appliance in the bedroom or adjoining bathroom.
  • Revised lumber capacities have changed the span lengths for floor joists, ceiling joists, and rafters in the prescriptive tables of the IRC.
  • New sections and tables provide prescriptive methods for posts, beams, joists, and connections in deck construction.
  • The girder and header span tables of Chapter 5 have been moved into Chapter 6. Multi-ply and single header tables are combined. A new section describing rim board headers is added.

ISBN-10: 1609834704
ISBN-13: 978-1609834708

Take our 2015 Free B1 Residential Building Inspector Practice Exam.

Pass this 10 question free ICC 2015 B1 practice test to glimpse where you stand! These sample 2015 ICC B1 practice questions are similar to the problems you will encounter when taking your actual ICC B1 2018 Certification exam.

If you answer eight or more of these practice questions correctly, congratulations, you are in pretty good shape.

However, if you miss three or more questions, get this course, you are in danger of failing your ICC Exam.

The work for which a permit is issued must be begun and finished within _____ of the permit being issued.

Correct! Wrong!

An application for a permit for any proposed work shall be deemed to have been abandoned 180 days after the date of filing unless such application has been pursued in good faith or a permit has been issued; except that the building official is authorized to grant one or more extensions of time for additional periods not exceeding 180 days each. The extension shall be requested in writing and justifiable cause demonstrated.

2015 IRC R105.3.2 Time limitation of application.
Section R105, Permits.
Chapter 1, Scope and administration.

Under which category are urban and suburban areas, with numerous closely spaced obstructions having the size of single-family dwellings or larger sited?

Correct! Wrong!

Exposure B. Urban and suburban areas, wooded areas or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. Exposure B shall be assumed unless the site meets the definition of another type exposure.

2015 IRC R301.2.1.4 Exposure category.
Section 301, Design criteria.
Chapter 3, Building planning.

In Seismic Design Categories D0, D1 and D2, slabs on ground cast monolithically with turned-down footings must have a min. of one No. 4 bar at the __________ of the footing.

Correct! Wrong!

In Seismic Design Categories D0, D1 and D2, slabs on ground cast monolithically with turned-down footings shall have a minimum of one No. 4 bar at the top and the bottom of the footing or one No. 5 bar or two No. 4 bars in the middle third of the footing depth.

Where the slab is not cast monolithically with the footing, No. 3 or larger vertical dowels with standard hooks on each end shall be installed at not more than 4 feet (1,219 mm) on center in accordance with Figure R403.1.3, Detail 2. Standard hooks shall comply with Section R608.5.4.5.

2015 IRC R403.1.3.3 Slabs-on-ground with turned-down footings.
Section R403, Footings.
Chapter 4, Foundations.

Exterior footings must be placed a min. of _____ below the undisturbed ground surface.

Correct! Wrong!

Exterior footings shall be placed not less than 12 inches (305 mm) below the undisturbed ground surface. Where applicable, the depth of footings shall also conform to Sections R403.1.4.1 through R403.1.4.2.

2015 IRC R403.1.4 Minimum depth.
Section R403, Footings.
Chapter 4, Foundations.

The height of backfill against a wood foundation wall must not exceed _____ if they are not designed and installed in accordance with AWC PW.

Correct! Wrong!

For wood foundations that are not designed and installed in accordance with AWC PWF, the height of backfill against a foundation wall shall not exceed 4 feet (1,219 mm). When the height of fill is more than 12 inches (305 mm) above the interior grade of a crawl space or floor of a basement, the thickness of the plywood sheathing shall meet the requirements of Table R404.2.3.

2015 IRC R404.2.3 Height of backfill.
Section 404, Foundation and Retaining Walls.
Chapter 4, Foundations.

What is the maximum allowable span where 2 x 10 floor joists of No. 2 Douglas fir-larch spaced at 16 inches on center, supporting a dead load of 20 psf are used?

Correct! Wrong!

The maximum allowable span where 2 x 10 - floor joists of No. 2 Douglas fir-larch spaced at 16 inches on center, supporting a dead load of 20 psf are used is 14 feet, 3 inches.

2015 IRC Table R502.3.1(2) Floor joist spans for common lumber species (Residential living areas, live load = 40 psf, L/D = 360).
Section R502, Wood floor framing.
Chapter 5, Floors.

Exterior walls parallel to a braced wall line must be offset a max. of _____ from the designated braced wall line location.

Correct! Wrong!

Exterior walls parallel to a braced wall line shall be offset not more than 4 feet (1,219 mm) from the designated braced wall line location as shown in Figure R602.10.1.1. Interior walls used as bracing shall be offset not more than 4 feet (1,219 mm) from a braced wall line through the interior of the building as shown in Figure R602.10.1.1.

2015 IRC R602.10.1.2 Offsets along a braced wall line.
Section 602, Wood wall framing.
Chapter 6, Wall Construction.

A single top plate is permitted in a wood stud bearing wall where the rafters or joists are centered over the studs with a max. tolerance of __________.

Correct! Wrong!

Wood stud walls shall be capped with a double top plate installed to provide overlapping at corners and intersections with bearing partitions. End joints in top plates shall be offset not less than 24 inches (610 mm). Joints in plates need not occur over studs. Plates shall be not less than 2-inches (51 mm) nominal thickness and have a width not less than the width of the studs.

Exception: A single top plate used as an alternative to a double top plate shall comply with the following:

1. The single top plate shall be tied at corners, intersecting walls, and at in-line splices in straight wall lines in accordance with Table R602.3.2.

2. The rafters or joists shall be centered over the studs with a tolerance of not more than 1 inch (25 mm).

3. Omission of the top plate is permitted over headers where the headers are adequately tied to adjacent wall sections in accordance with Table R602.3.2.

2015 IRC R602.3.2 Top plate. EXC.
Section R602, Wood wall framing.
Chapter 6, Wall construction.

Screws used to attach gypsum board and gypsum panel products to wood framing must penetrate the wood a min. of __________.

Correct! Wrong!

Screws for attaching gypsum board and gypsum panel products to wood framing shall be Type W or Type S in accordance with ASTM C 1002 and shall penetrate the wood not less than 5/8 inch (15.9 mm). Gypsum board and gypsum panel products shall be attached to cold-formed steel framing with minimum No. 6 screws. Screws for attaching gypsum board and gypsum panel products to cold-formed steel framing less than 0.033 inch (1 mm) thick shall be Type S in accordance with ASTM C 1002 or bugle head style in accordance with ASTM C 1513 and shall penetrate the steel not less than 3/8 inch (9.5 mm). Screws for attaching gypsum board and gypsum panel products to cold-formed steel framing 0.033 inch to 0.112 inch (1 mm to 3 mm) thick shall be in accordance with ASTM C 954 or bugle head style in accordance with ASTM C 1513. Screws for attaching gypsum board and gypsum panel products to structural insulated panels shall penetrate the wood structural panel facing not less than 7/16 inch (11.1 mm).

2015 IRC R702.3.5.1 Screw fastening.
Section R702, Interior covering.
Chapter 7, Wall covering.

A fire-resistance rating of _____ is required for fire-resistance rating projections of dwellings with fire sprinklers that have a min. fire separation distance of 2 feet.

Correct! Wrong!

A fire-resistance rating of 1-hour is required for fire-resistance rating projections of dwellings with fire sprinklers that have a min. fire separation distance of 2 feet.

Note a. For residential subdivisions where all dwellings are equipped throughout with an automatic sprinkler system installed in accordance with Section P2904, the fire separation distance for nonrated exterior walls and rated projections shall be permitted to be reduced to 0 feet, and unlimited unprotected openings and penetrations shall be permitted, where the adjoining lot provides an open setback yard that is 6 feet or more in width on the opposite side of the property line.

2015 IRC Table R302.1(2) Exterior walls- dwellings with fire sprinklers.
Section 302, Fire-resistant construction.
Chapter 3, Building planning.