Sale!

ICC R5 (RCI) Residential Combination Exam Course!

Become a  R5 Residential Building Inspector!

Complete our self-paced Residential Building Inspector Training Course then take your actual ICC online exam via ICC PRONTO. Rapidly become ICC certified without ever having to leave the comfort of your home or office.

Refresh your IRC code knowledge, successfully pass your ICC R5 Residential Building Inspector Exams. Our comprehensive interactive Building Inspector exam preparation program is your best, most affordable path to guarantee ICC certification!

Many inspectors additionally use ICC R5 Residential Building Certification as a crucial part of their Inspector Certification portfolio.

 

$675.00 $575.00

Add to cart
Category:

Course Outline

ICC R5 Residential Combination Inspector (RCI) package. Everything needed to achieve R5 Status. PASS YOUR ICC B1, M1, P1, and E1 EXAM. Our 100% money-back guarantee backs this course. Save $100 when you order our R5 package!

Achieving an ICC R5 Residential Combination Designation demonstrates your proficiency and flexibility in diverse building safety disciplines that opens many doors to a broad array of job opportunities.

Show any potential employer that you mean business when you possess ICC R5 certification status. As an ICC R5 Residential Combination Inspector, you can inspect any residential building project!

R5 RESIDENTIAL COMBINATION INSPECTOR (RCI) INCLUDES: 1) B1 Course. 2) M1 Course.  3) P1 Course. 4) E1 Course.


First, pass your ICC B1 Residential Building Inspector exam. Our comprehensive interactive Combination Residential Inspector exam preparation course is your best, most affordable path to guarantee ICC B1 certification!

 

ICC B1 Residential Building Inspector Certification Course
Pass the ICC B1 exam the first time you test with our ICC Exam prep course.

 

Click Here For Details

THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2015 (IRC) INTERNATIONAL RESIDENTIAL CODE. IF YOU DO NOT OWN A COPY OF THE CODEBOOK, YOU SHOULD ACQUIRE ONE IMMEDIATELY.


Next, pass your ICC M1 Residential Mechanical Inspector exam. Our comprehensive interactive Combination Residential Inspector exam preparation course is your best, most affordable path to guarantee ICC M1 certification!

ICC M1 Residential Mechanical Inspector Certification Course
Pass the ICC M1 exam the first time you test with our ICC Exam prep course.

 

Click Here For Details

THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2015 (IRC) INTERNATIONAL RESIDENTIAL CODE. IF YOU DO NOT OWN A COPY OF THE CODEBOOK, YOU SHOULD ACQUIRE ONE IMMEDIATELY.


Next, pass your ICC P1 Residential Plumbing Inspector exam. Our comprehensive interactive R5 Combination Residential Inspector exam preparation course is your best, most affordable path to guarantee ICC P1 certification!

ICC P1 Residential Plumbing Inspector Certification Course
Pass the ICC P1 exam the first time you test with our ICC Exam prep course.

 

Click Here For Details

THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2015 (IRC) INTERNATIONAL RESIDENTIAL CODE. IF YOU DO NOT OWN A COPY OF THE CODEBOOK, YOU SHOULD ACQUIRE ONE IMMEDIATELY.


Last, pass your ICC E1 Residential Electrical Inspector exam. Our comprehensive interactive R5 Combination Residential Inspector exam preparation course is your best, most affordable path to guarantee ICC E1 certification!

ICC E1 Residential Electrical Inspector Certification Course
Pass the ICC E1 exam the first time you test with our ICC Exam prep course.

 

Click Here For Details

THE E1 EXAM PROGRAMS REQUIRE YOU TO HAVE A COPY OF THE 2015 (IRC) INTERNATIONAL RESIDENTIAL CODE. AND 2014 (NEC) NATIONAL ELECTRIC CODE IF YOU DO NOT OWN A COPY OF THESE CODEBOOKS, YOU SHOULD ACQUIRE THEM IMMEDIATELY.

Codebook - 2015 IRC

2015 IRC SOFTCOVER 

You must have a copy of the 2015 IRC to use this program!

Pass the ICC B1, M1, P1, and E1 Exam. The ICC Inspector Certification exam is an open book test.

You must possess a copy of the 2105 IRC when taking your ICC B1, M1, P1, and E1 Residential Inspector Exams.

$144.00

Add to cart
Category:

Course Outline

the 2015 IRC is a REQUIRED CODEBOOK for 2015, B1, M1, P1, and E1 Residential Building Inspector Exams.

This comprehensive code compiles all building, plumbing, mechanical, fuel gas and electrical requirements for non-commercial one- and two-family dwellings in one convenient code. The regulations cover dwellings and townhouses up to three stories.

  • The 2015 IRC® contains many important changes including:
  • Common walls separating townhouses must now be rated for 2 hours when an automatic fire sprinkler system is not installed.
  • Remodeling of an existing basement does not trigger the emergency escape and rescue opening requirements unless a new bedroom is created.
  • Ramps that do not serve the required egress door are now permitted to have a slope not greater than 1 unit vertical in 8 units horizontal.
  • Carbon monoxide alarms now require connection to the house wiring system with battery backup. A carbon monoxide alarm is required in bedrooms when there is a fuel-
  • fired appliance in the bedroom or adjoining bathroom.
  • Revised lumber capacities have changed the span lengths for floor joists, ceiling joists, and rafters in the prescriptive tables of the IRC.
  • New sections and tables provide prescriptive methods for posts, beams, joists, and connections in deck construction.
  • The girder and header span tables of Chapter 5 have been moved into Chapter 6. Multi-ply and single header tables are combined. A new section describing rim board headers is added.

ISBN-10: 1609834704
ISBN-13: 978-1609834708

Codebook - 2014 NEC

2014 NEC SOFTCOVER

You must have a copy of the 2014 NEC to use this program!

Pass either the ICC E1 Residential Electrical Inspector Exam or Pass the ICC E2 Commercial Electrical Inspector exam.

The ICC electrical Inspector Certification exams is an open book code test.

You must possess a copy of the 2014 NEC when taking the ICC E1 or E2 Electrical Inspector exam.

$129.95

Add to cart
Category:

Course Outline

The 2014 NEC is a REQUIRED CODEBOOK for anyone taking the 2014 E2 Commercial Electrical Inspectors exam.

The 2014 National Electrical Code contains hundreds of significant revisions encompassing new technology and improved safety for electrical personnel and consumers. Revisions in the 2014 NEC impact residential, commercial, and industrial installations. Stay current and update today! (Softbound, 910 pp., 2014)

Major changes in the 2014 NEC include:

expanded AFCI and GFCI protection in homes; new methods to distribute low voltage power; new practices to ensure the safety of photovoltaic electrical systems; plus electrical worker safety, sustainable energy systems, and more!

First-time articles introduce new coverage in growth areas:

  • Low Voltage Direct Current Distribution Systems (Article 393)
  • Modular Data Centers (Article 646)
  • Fire Resistive Cable Systems (Article 728)
  • Energy Management Systems (Article 750)

 

ISBN-13: 978-1455916467
ISBN-10: 1455916463

Free ICC B1 Practice Quiz

Ten free ICC B1 Residential Building Inspector Exam Questions:

Pass this free ICC B1 exam to glimpse where you stand! These sample B1 Residential Building Inspector practice questions are similar to the ones you will encounter when taking your actual ICC B1 Certification exam.

If you readily answer eight or more of these practice questions correctly, congratulations, you are in pretty good shape.

However, if you miss three or more questions, you are in danger of failing your ICC Exam.

 

The work for which a permit is issued must be begun and finished within _____ of the permit being issued.

Correct! Wrong!

An application for a permit for any proposed work shall be deemed to have been abandoned 180 days after the date of filing unless such application has been pursued in good faith or a permit has been issued; except that the building official is authorized to grant one or more extensions of time for additional periods not exceeding 180 days each. The extension shall be requested in writing and justifiable cause demonstrated.

2015 IRC R105.3.2 Time limitation of application.
Section R105, Permits.
Chapter 1, Scope and administration.

Under which category are urban and suburban areas, with numerous closely spaced obstructions having the size of single-family dwellings or larger sited?

Correct! Wrong!

Exposure B. Urban and suburban areas, wooded areas or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. Exposure B shall be assumed unless the site meets the definition of another type exposure.

2015 IRC R301.2.1.4 Exposure category.
Section 301, Design criteria.
Chapter 3, Building planning.

In Seismic Design Categories D0, D1 and D2, slabs on ground cast monolithically with turned-down footings must have a min. of one No. 4 bar at the __________ of the footing.

Correct! Wrong!

In Seismic Design Categories D0, D1 and D2, slabs on ground cast monolithically with turned-down footings shall have a minimum of one No. 4 bar at the top and the bottom of the footing or one No. 5 bar or two No. 4 bars in the middle third of the footing depth.

Where the slab is not cast monolithically with the footing, No. 3 or larger vertical dowels with standard hooks on each end shall be installed at not more than 4 feet (1,219 mm) on center in accordance with Figure R403.1.3, Detail 2. Standard hooks shall comply with Section R608.5.4.5.

2015 IRC R403.1.3.3 Slabs-on-ground with turned-down footings.
Section R403, Footings.
Chapter 4, Foundations.

Exterior footings must be placed a min. of _____ below the undisturbed ground surface.

Correct! Wrong!

Exterior footings shall be placed not less than 12 inches (305 mm) below the undisturbed ground surface. Where applicable, the depth of footings shall also conform to Sections R403.1.4.1 through R403.1.4.2.

2015 IRC R403.1.4 Minimum depth.
Section R403, Footings.
Chapter 4, Foundations.

The height of backfill against a wood foundation wall must not exceed _____ if they are not designed and installed in accordance with AWC PW.

Correct! Wrong!

For wood foundations that are not designed and installed in accordance with AWC PWF, the height of backfill against a foundation wall shall not exceed 4 feet (1,219 mm). When the height of fill is more than 12 inches (305 mm) above the interior grade of a crawl space or floor of a basement, the thickness of the plywood sheathing shall meet the requirements of Table R404.2.3.

2015 IRC R404.2.3 Height of backfill.
Section 404, Foundation and Retaining Walls.
Chapter 4, Foundations.

What is the maximum allowable span where 2 x 10 floor joists of No. 2 Douglas fir-larch spaced at 16 inches on center, supporting a dead load of 20 psf are used?

Correct! Wrong!

The maximum allowable span where 2 x 10 - floor joists of No. 2 Douglas fir-larch spaced at 16 inches on center, supporting a dead load of 20 psf are used is 14 feet, 3 inches.

2015 IRC Table R502.3.1(2) Floor joist spans for common lumber species (Residential living areas, live load = 40 psf, L/D = 360).
Section R502, Wood floor framing.
Chapter 5, Floors.

Exterior walls parallel to a braced wall line must be offset a max. of _____ from the designated braced wall line location.

Correct! Wrong!

Exterior walls parallel to a braced wall line shall be offset not more than 4 feet (1,219 mm) from the designated braced wall line location as shown in Figure R602.10.1.1. Interior walls used as bracing shall be offset not more than 4 feet (1,219 mm) from a braced wall line through the interior of the building as shown in Figure R602.10.1.1.

2015 IRC R602.10.1.2 Offsets along a braced wall line.
Section 602, Wood wall framing.
Chapter 6, Wall Construction.

A single top plate is permitted in a wood stud bearing wall where the rafters or joists are centered over the studs with a max. tolerance of __________.

Correct! Wrong!

Wood stud walls shall be capped with a double top plate installed to provide overlapping at corners and intersections with bearing partitions. End joints in top plates shall be offset not less than 24 inches (610 mm). Joints in plates need not occur over studs. Plates shall be not less than 2-inches (51 mm) nominal thickness and have a width not less than the width of the studs.

Exception: A single top plate used as an alternative to a double top plate shall comply with the following:

1. The single top plate shall be tied at corners, intersecting walls, and at in-line splices in straight wall lines in accordance with Table R602.3.2.

2. The rafters or joists shall be centered over the studs with a tolerance of not more than 1 inch (25 mm).

3. Omission of the top plate is permitted over headers where the headers are adequately tied to adjacent wall sections in accordance with Table R602.3.2.

2015 IRC R602.3.2 Top plate. EXC.
Section R602, Wood wall framing.
Chapter 6, Wall construction.

Screws used to attach gypsum board and gypsum panel products to wood framing must penetrate the wood a min. of __________.

Correct! Wrong!

Screws for attaching gypsum board and gypsum panel products to wood framing shall be Type W or Type S in accordance with ASTM C 1002 and shall penetrate the wood not less than 5/8 inch (15.9 mm). Gypsum board and gypsum panel products shall be attached to cold-formed steel framing with minimum No. 6 screws. Screws for attaching gypsum board and gypsum panel products to cold-formed steel framing less than 0.033 inch (1 mm) thick shall be Type S in accordance with ASTM C 1002 or bugle head style in accordance with ASTM C 1513 and shall penetrate the steel not less than 3/8 inch (9.5 mm). Screws for attaching gypsum board and gypsum panel products to cold-formed steel framing 0.033 inch to 0.112 inch (1 mm to 3 mm) thick shall be in accordance with ASTM C 954 or bugle head style in accordance with ASTM C 1513. Screws for attaching gypsum board and gypsum panel products to structural insulated panels shall penetrate the wood structural panel facing not less than 7/16 inch (11.1 mm).

2015 IRC R702.3.5.1 Screw fastening.
Section R702, Interior covering.
Chapter 7, Wall covering.

A fire-resistance rating of _____ is required for fire-resistance rating projections of dwellings with fire sprinklers that have a min. fire separation distance of 2 feet.

Correct! Wrong!

A fire-resistance rating of 1-hour is required for fire-resistance rating projections of dwellings with fire sprinklers that have a min. fire separation distance of 2 feet.

Note a. For residential subdivisions where all dwellings are equipped throughout with an automatic sprinkler system installed in accordance with Section P2904, the fire separation distance for nonrated exterior walls and rated projections shall be permitted to be reduced to 0 feet, and unlimited unprotected openings and penetrations shall be permitted, where the adjoining lot provides an open setback yard that is 6 feet or more in width on the opposite side of the property line.

2015 IRC Table R302.1(2) Exterior walls- dwellings with fire sprinklers.
Section 302, Fire-resistant construction.
Chapter 3, Building planning.

You may also need…

Go To Cart